University of Minnesota
Development of an SLA Printable Resin for Modeling Mild and Moderate Aortic Stenosis
Abstract
dc:description.abstractThe heart is one of the most important organs in the human body, and heart disease is the leading cause of death in the world. Particularly, aortic stenosis (AS), characterized by the narrowing of the aortic valve (AV) opening during ventricular ejection, remains a major cause of global cardiovascular morbidity and mortality. While advanced modeling of severe AS has significantly aided clinical characterization, the biomechanical behavior of mild to moderate stenosis remains understudied. This research focuses on the development and optimization of a biomimetic photopolymer resin designed to replicate the mechanical properties of mild and moderate stenotic aortic tissue for use in Stereolithography (SLA) 3D printing. Formlab’s BioMed Flex 80A and Elastic 50A were extensively evaluated as base materials for modeling native heart tissue. Furthermore, tensile strength, Young’s modulus, and transparency were identified as critical parameters for success. Both tensile strength and Young’s modulus were obtained by tensile testing using an Admet eXpert 5900 Series Dynamic Testing Systems Tester, following a modified ASTM standard D638 protocol. To account for the nonlinear deformation inherent in these elastomers, Young’s modulus was calculated at 0.11 strain rather than the standard 0.2% offset. Methods of altering properties of Elastic 50A and BioMed Flex 80A using post printing processes of: Isopropyl Alcohol (IPA) exposure duration, UV cure time and UV medium, proved ineffective. Consequently, chemical additives were introduced to the BioMed Flex 80A matrix: 2-Hydroxyethyl Methacrylate (HEMA) and Butyl Methacrylate (BMA). While BMA exhibited a softening effect, HEMA successfully increased material stiffness. Experimental results demonstrated that a 15% mass concentration of HEMA in BioMed Flex 80A yielded a Young’s modulus of 15 MPa, closely approximating the mechanical profile of native aortic cusps. Furthermore, this 15% concentration was identified as the upper threshold for successful SLA printing. All functional prints exhibited refractive index (RI) values between 1.41 and 1.44, confirming their suitability for optical flow studies and cardiovascular modeling.
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Borman, Chayton
Subjects
dc:subject × 5Rights
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- Dc Identifier Citation
- Borman, Chayton. (2026). Development of an SLA Printable Resin for Modeling Mild and Moderate Aortic Stenosis. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/281705.