Back to search

University of Minnesota

Patient-Specific Monte Carlo Dosimetric Evaluation of Heterogeneity effects in Tile - based Cesium-131 Permanent Intracranial Brachytherapy with Clinical Validation

Abstract

dc:description.abstract

Intracranial brachytherapy using cesium-131(¹³¹Cs) GammaTiles has emerged as a promising treatment approach for the management of brain lesions, such as glioblastoma multiform demonstrating improved overall survival outcomes. Current clinical Treatment Planning Systems (TPS) for permanent intracranial ¹³¹Cs implants primarily rely on the AAPM TG-43 formalism, which assumes a homogeneous water-equivalent medium and neglects patient-specific tissue heterogeneity. Previous investigators have demonstrated significant discrepancies between TG-43 based dose calculations and material-specific Monte Carlo (MC) simulations. This dissertation aims to quantify the dosimetric impact of tissue heterogeneity on target coverage and organ-at-risks (OAR) sparing using a high-fidelity MC framework with retrospective patient CT DICOM datasets of intracranial ¹³¹Cs implants. Furthermore, the theoretical applicability of the Linear Boltzmann Transport Equation (LBTE) is explored as a deterministic framework for low-energy ¹³¹Cs dose calculations, motivated by the computational limitations of MC methods for routine clinical implementation. The MCNP6.3 MC radiation transport code was benchmarked and validated experimentally. Gafchromic film calibration and dosimetric measurements were performed to support MC validation. A patient-specific dosimetric workflow was developed using CERR (Computational Environment for Radiological Research) integrated with MATLAB and MCNP6.3 platform. The 3D voxelized lattice phantom was created using the patient’s clinical DICOM-RT data by Hounsfield Units/density conversion for heterogeneous transport simulations. Dose distributions calculated using MCNP were compared against clinical TPS estimates in both homogeneous and heterogeneous geometrics for single- and multi-source implant configurations. Transitioning from homogeneous water-equivalent calculations to heterogeneous MC modeling revealed substantial dosimetric deviations. A 3.21 -fold (221%) increase in the mean dos to skull was observed relative to TPS predictions. Moreover, this work identified an “energy sink” effect, whereby enhanced photoelectric absorption within the skull attenuated photon transport and produces dose showering in adjacent target regions. Consequently, a 23.51% reduction in V₁₀₀ target coverage was measured for the High-Risk Clinical Target Volume (HRCTV) compared with TG-43 based TPS estimates. Conversely, the skull provided partial shielding for distal OAR, reducing the scalp dose by up to 70%. Theoretical analysis further suggests that the LBTE may provide a viable deterministic alternative for LE dose calculations, provided that transport parameters are carefully modeled and rigorously validated experimentally. This dissertation presents the first independent MCNP-based proof-of-concept cross-validation of heterogeneity effects in patient-specific intracranial ¹³¹Cs brachytherapy geometry. The finding demonstrates that conventional TG-43 based clinical model may substantially overestimates tumor target coverage while underestimating the likelihood of osteoradionecrosis. These results establish a strong clinical rationale for the implementation of heterogeneity-corrected dose calculation algorithms in intracranial brachytherapy to improve both treatment accuracy and patient safety and the test case could be used for benchmarking and validating MBDCAs. Additionally, this work introduces a theoretical exploration of LBTE-based absorbed dose estimation of heterogeneous ¹³¹Cs intracranial implant as a potential alternative to MC methods. Collectively, this work provides a foundation for the development of clinically implementable heterogeneity aware dose calculation frameworks that may improve treatment accuracy, tumor control, and toxicity prediction in intracranial brachytherapy.

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Adhikari, Tirthraj

Subjects

dc:subject × 5

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Dc Identifier Citation
Adhikari, Tirthraj. (2026). Patient-Specific Monte Carlo Dosimetric Evaluation of Heterogeneity effects in Tile - based Cesium-131 Permanent Intracranial Brachytherapy with Clinical Validation. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/282281.

Chain of custody

source
Harvested from
University of Minnesota
Base URL
conservancy.umn.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Adhikari, Tirthraj. Patient-Specific Monte Carlo Dosimetric Evaluation of Heterogeneity effects in Tile - based Cesium-131 Permanent Intracranial Brachytherapy with Clinical Validation. 2026. https://hdl.handle.net/11299/282281