Back to search

University of Minnesota

Low Frequency Longitudinally-Detected Electron Paramagnetic Resonance for the Detection of Iron Oxide Nanoparticles in Tissues

Abstract

dc:description.abstract

Unfortunately, ~20% of kidneys donated for transplant are discarded due to short storage viability (~24-36 h). Cryopreservation decreases storage temperatures below -140°C, enabling storage of kidneys for months to years. To re-warm cryopreserved kidneys and other organs without ice formation and cracking, fast and even warming is needed. For this, iron oxide nanoparticles (IONPs) can be perfused into them prior to cooling, then radiofrequency waves can be applied to rapidly rotate their magnetic moments, causing local heating around IONPs and organ re-warming. Despite initial success of this method in rat kidneys, the complex behavior of IONPs (uneven particle distribution, aggregation, etc.) limits reproducibility and is a major bottleneck in its translation to human organs. Currently there is no low-cost method to nondestructively track IONPs in organs across concentrations of interest. Thus, there is a need for precise monitoring of IONP concentrations (1) after perfusion, to ensure even IONP distribution and therefore even kidney heating and viability, and (2) prior to transplant, to prevent potential IONP-related iron toxicity post-transplant. To address this, our lab has developed a low-cost, longitudinally detected electron paramagnetic resonance (LOD-EPR) system that can directly detect electrons in IONPs. This thesis presents the development of LOD-EPR into an IONP quantification system in tissues. We validate the relationship of the LOD-EPR signal to IONP concentration in solution and in rat kidney biopsies and compare performance to benchtop nuclear magnetic resonance (NMR) T₁ relaxometry. A second-generation version of the initial system is built with improved sensitivity, larger maximum sample size, and modularity in terms of frequency and coil geometries available for use. The system is made to eventually be turned into an imaging system. Lastly, a method for B₁-encoding and slice- or slab-selection is developed and tested for feasibility on a 9.4T MRI system for later testing in LOD-EPR imaging of IONPs. By enabling IONP monitoring during the cryopreservation process, IONP synthesis, kidney perfusion, and radiofrequency heating parameters can be optimized for increased kidney viability during re-warming. This will ultimately expedite development of organ cryopreservation to increase transplant availability. Furthermore, the techniques and hardware presented here are not only limited to IONP quantification as LOD-EPR functions more generally for quantification and eventual imaging of other EPR-active substances such as probes for tissue oximetry, oxidative stress, pH, etc.

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Kantesaria, Saurin

Subjects

dc:subject × 6

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Dc Identifier Citation
Kantesaria, Saurin. (2025). Low Frequency Longitudinally-Detected Electron Paramagnetic Resonance for the Detection of Iron Oxide Nanoparticles in Tissues. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/283103.

Chain of custody

source
Harvested from
University of Minnesota
Base URL
conservancy.umn.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Kantesaria, Saurin. Low Frequency Longitudinally-Detected Electron Paramagnetic Resonance for the Detection of Iron Oxide Nanoparticles in Tissues. 2025. https://hdl.handle.net/11299/283103