University of Minnesota
Droplet Size Distribution Characterization for Agricultural Flat Fan Sprays
Abstract
dc:description.abstractAgricultural flat-fan sprays are widely used to apply crop protection products and fertilizers on the fields. To optimize application efficacy and reduce environmental contamination, the volumetric droplet size distribution (VDSD), which can range from micrometers to millimeters, needs to be characterized and controlled as not all droplet sizes are suitable for products application and retention. This dissertation presents a framework for capturing the volumetric size distribution curves of flat-fan sprays by nondimensionalization using the Sauter mean diameter (D₃,₂) and developing a scaling relationship for predicting D₃,₂. That framework is then applied to study spray characteristics of different flat-fan systems. The first study focuses on developing the framework based on the conservation of energy involved in spraying, testing it on 3 different common herbicidal mixes and 3 agricultural flat-fan nozzles with different internal geometries to demonstrate the broad applicability of the scaling. The second study utilizes that framework to study how oil emulsions within tank mixes affect the final spray droplet size distribution by varying an emulsion volume fraction across 5 orders of magnitude. In the process, five common distribution fits - spline, Beta, Weibull/Rosin-Rammler, Lognormal, and Two-parameter Gamma - were employed to fit the dimensionless VDSDs and evaluated using root mean square error to see which can accurately describe the dimensionless VDSDs; the spline, Beta, and Weibull/Rosin-Rammler outperformed the other two. Oil droplet size distribution curves for different emulsion concentrations were also captured, revealing that the oil distribution curves retain the same shape across all concentrations and indicating an increase in emulsion number density. Finally, the last study looks into the performance of jet-deflection flat-fan nozzles when applying 3 different polymeric tank mixes (PEG 6 kDa, xanthan gum, and guar gum) at different concentrations. All tank mixes were characterized for their surface tension, shear viscosity, extensional relaxation time, and extensional viscosity to see how each parameter affects the spray VDSD. The Buckingham Pi theorem was applied to develop 3 multivariate power law scalings for D₃,₂, span, and %Vol ≤ 150 μm with 5 dimensionless numbers - shear Reynolds, Weber, Euler, Trouton, and jet-diameter-to-jet-to-plate-distance ratio - as variables
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Nguyen, Long
Subjects
dc:subject × 6Rights
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- Dc Identifier Citation
- Nguyen, Long. (2026). Droplet Size Distribution Characterization for Agricultural Flat Fan Sprays. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/283447.