dc:description.abstract

A walkway tribometer measures the coefficient of friction between flooring material and a test foot. The value of the coefficient of friction is an indicator as to whether the flooring surface is slippery and has a propensity to cause slip and falls. This study determined that one style of tribometer, an XL Tribometer, mimics the heel-to-floor interaction of the human heel strike. High speed video footage revealed that the test foot strikes the surface and rotates so that full engagement occurs before sliding thus mimicking the affect of a human ankle. The test foot accelerates forward as would be expected during a human slip event. The manufacturer’s reported impact speed of 11 in/s, when set to the operating pressure of 25psi, was found to be much lower than measured speeds of three calibrated tribometers. Three XL tribometers were tested and provided a range of impact speeds from 17.4 to 22.7 in/s (n=540) when set to the operating pressure of 25 psi. The pressure setting was found to have a significant effect on the impact speed while the mast angle had an insignificant affect. A review of human walking studies revealed a range of pedestrian heel impact speeds on the order of 19.4 to 45.3 in/s during normal human ambulation activities. These tribometers fell on the low side of this speed range. A sensitivity study showed that the measured value of the coefficient of friction tends to decrease with a higher impact speed. This COF decrease was on the order of 0.02 and below the machine resolution and considered inconsequential within the walkway safety community.

Degree

thesis:*
Name thesis:degree_name
Master of Science in Mechanical Engineering (MSME)
Discipline thesis:degree_discipline
Engineering
Grantor
University of North Florida. School of Engineering
Date dc:date.issued
Spring

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Baker, Henry Thomas
  • Baker, Henry Thomas, 1966-
Advisors dc:contributor.advisor
  • Eason, Paul
  • Tiryakioglu, Murat
  • Balasubramanian, Chitra
Contributors dc:contributor
  • Dr. Paul Eason
  • Dr. Murat Tiryakioglu
  • Dr. Chitra Balasubramanian

Subjects

dc:subject × 6

Rights

dc:rights

Identifiers

dc:identifier.*
Repository record dc:identifier
https://digitalcommons.unf.edu/etd/484

Chain of custody

source
Harvested from
University of North Florida
Base URL
digitalcommons.unf.edu/do/oai/
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Baker, Henry Thomas; Baker, Henry Thomas, 1966-. A Study of Walkway Safety and Evaluation of Tribological Test Equipment. University of North Florida. School of Engineering, https://digitalcommons.unf.edu/etd/484