Back to search

University of North Texas

Wear, Friction and High Shear Strain Deformation of Metallic Glasses

Abstract

dc:description

In this work, wear and scratch behavior of four different bulk metallic glasses (BMGs) namely Zr41.2Cu12.5Ni10Ti13.8Be22.5 (LM 1), Zr57Cu15.4Ni12.6Al10Nb5 (LM 106), Ni60Pd20P17B3 (Ni-BMG), and Pt57.5Cu14.7Ni5.3P22.5 (Pt-BMG) were compared. Shear band formation on the edges of the scratch groove with spallation was found to be the primary failure mechanism in progressive scratch tests. The wear behavior and the scratch response of model binary Ni-P metallic glasses was systematically studied as a function of composition, with amorphous alloy formation over the narrow range of 10 at% to 20 at% phosphorus. Pulsed current electrodeposition was used to obtain these binary amorphous alloys, which offers a facile and versatile alternative to conventional melt quenching route. The electrodeposited metallic glasses (EMGs) showed hardness values in the range of 6.6-7.4 GPa, modulus in the range of 155-163 GPa, and friction coefficient around 0.50. Among the studied alloys, electrodeposited Ni80P20 showed the lowest wear rate. The wear mechanism was determined to be extensive plastic deformation along with mild ploughing, micro tears, and formation of discontinuous lubricious oxide patches. The effect of phosphorus content on the structure, mechanical properties, and the tribological response was systematically investigated for biocompatible Co-P metallic glasses. With increase in phosphorus content, there was an increase in hardness, hardness/modulus, wear resistance, and scratch resistance following the trend: Co80P20 > Co90P10 > Pure Co. The Co-P electrodeposited amorphous alloys showed enhanced wear resistance that was two orders of magnitude better than SS 316 and Ti-based alloys in simulated physiological environment. The wear mechanisms were determined to be a combination of abrasive and surface fatigue wear in both dry and physiological environments. Decreased platelet adhesion and more extracellular matrix deposition indicated that Co80P20 electrodeposited alloy had excellent blood compatibility and pre-osteoblast adhesion response. These results suggest the potential use of Co-P metallic glasses as superior bio implant materials with better durability compared to the state-of-the-art.

Degree

thesis:*
Grantor dc:publisher
University of North Texas
Year dc:date
2022

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Pole, Mayur
Contributors dc:contributor
  • Mukherjee, Sundeep
  • Dahotre, Narendra
  • Scharf, Thomas W.
  • Aouadi, Samir
  • Narsazadani, Seifollah

Subjects

dc:subject × 8

Rights

dc:rights
Statement dc:rights
  • Public
  • Pole, Mayur
  • Copyright
  • Copyright is held by the author, unless otherwise noted. All rights Reserved.
Language dc:language
English

Identifiers

dc:identifier.*
Identifier
local-cont-no: submission_2774
https://digital.library.unt.edu/ark:/67531/metadc1944219/
ark: ark:/67531/metadc1944219

Chain of custody

source
Harvested from
University of North Texas
Base URL
digital.library.unt.edu/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Pole, Mayur. Wear, Friction and High Shear Strain Deformation of Metallic Glasses. University of North Texas, 2022. https://doi.org/10.12794/metadc1944219