University of North Texas
Development of a Computational Model to Assess the Thermal Impact of Photothermal Hearing Preservation Methods
Abstract
dc:descriptionMore than 30% of adults above 65 suffer from some form of hearing loss un the United States, which is expected to double by the year 2060. Hearing loss is often treated through the use of cochlear implants or hearing aids. Prevention methods such as photobiomodulation (PBM) could reduce the need for these treatments. PBM has been shown to reduce hearing loss in animals but has not been effective in human studies. However, human studies have been performed using shorter wavelengths and lower power densities, likely affecting the maximum temperature reached within the human cochlea. Maximum temperatures between 41°C and 42°C lead to increased release of heat shock protein 70 (HSP70) which protects cochlear tissue from damage caused by external stimuli. The human studies likely do not reach this temperature threshold, presenting a possible explanation for PBM being ineffective in humans. This research aims to develop a computational model to assess the thermal impact of photothermal hearing preservation methods on mice and human cochlea. The development of the heat transfer model required the selection of the most physiologically accurate boundary condition. An adiabatic, natural convection, and isothermal boundary condition at the cochlear walls were investigated. The temperature increase resulting from each boundary condition was compared to experimental ex vivo testing in a rat head. The experimental results aligned best with the simulation using the isothermal boundary condition.. Simulations were then performed for both mice and human cochlea to determine if there exists a different temperature response as a result of the lower power density used in human studies. The mouse cochlea model resulted in a maximum temperature over 41°C when exposed to a 120 mW input power over 5 minutes. The human cochlea model was performed using an input power of 7.5 mW over 4 minutes and resulted in a maximum temperature of 37.3°C, which is below the ideal range for HSP70 release. The results obtained indicate that PBM potentially involves a thermal response that may impact its effectiveness for use in hearing preservation.
Degree
thesis:*- Grantor dc:publisher
- University of North Texas
- Year dc:date
- 2025
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Ryan, Jeremy
- Contributors dc:contributor
-
- Esmailie, Fateme
- Yang, Yong
- Li, Lin
Subjects
dc:subject × 3Rights
dc:rights- Statement dc:rights
-
- Public
- Ryan, Jeremy
- Copyright
- Copyright is held by the author, unless otherwise noted. All rights Reserved.
- Language dc:language
- English
Identifiers
dc:identifier.*- Identifier
-
local-cont-no: submission_4559
ark: ark:/67531/metadc2566441