University of North Texas
A Cost-Effective Method for Fabricating Prosthetic Valves for Patient-Specific In-Vitro Studies
Abstract
dc:descriptionTranscatheter Aortic Valve Replacement (TAVR) is a minimally invasive treatment for aortic valve disease. However, it is known that there is some risk of thrombus formation post- TAVR. Studies using Machine Learning (ML) to evaluate post-TAVR thrombus formation have struggled from the lack of patient data, and methods such as computational fluid dynamics (CFD) are computationally expensive and slow as well as requiring simplifications that make models less representative of patient-specific valves. These difficulties can be overcome using particle image velocimetry (PIV) in tandem with a mock circulatory loop (MCL). Although this system enables direct experimentation and evaluation of patient-specific hemodynamics, challenges remain, particularly limited access to real transcatheter valves. There are significant external barriers to accessing TAVR valves for in-vitro experiments. New valves cost over $30,000, are typically restricted to use by surgeons, and even expired valves, suitable for in vitro testing, are nearly impossible to obtain. Major manufacturers such as Medtronic and Edwards Lifesciences have imposed strict access limitations, possibly to mitigate legal risks associated with unfavorable research findings. This highlights the need for another method to evaluate clinical outcomes which can reduce computational costs, and run times, while also creating more data to be utilized for algorithmic based approaches to improve clinical predictions. In this project, we present a process for fabricating a prosthetic valve replica, designed to closely mimic the hemodynamic of transcatheter aortic valves. Then, we will pair it with patient-specific aortic phantoms within a mock circulatory loop, thus creating an in-vitro platform for thrombosis risk assessment. The replica valve is created by first SLA printing the stent from gray resin, then the leaflets are created with the use of latex sheeting that is cut using a laser cutter. The insertion of this replica into our flow loop allows for evaluation of the hemodynamic environment including the measurement of pressure, shear stress, and velocity data. Through the implementation of PIV, we will evaluate flow stagnation zones, allowing for insight into shear-induced platelet activation and thrombogenicity. Once these valves are validated by existing TAVR, the data provided by this valve will also be valuable in computational validation, providing critical data for CFD or fluid-structure interaction (FSI) models. These valves will provide a platform for future research on thrombosis and increase accessibility of patient data from cross analysis in the future.
Degree
thesis:*- Grantor dc:publisher
- University of North Texas
- Year dc:date
- 2026
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Fink, Rowan 2002-
- Contributors dc:contributor
-
- Ecker, Melanie J.
- Esmailie, Fateme
- Jafari, Amir
Subjects
dc:subject × 4Rights
dc:rights- Statement dc:rights
-
- Public
- Fink, Rowan 2002-
- Copyright
- Copyright is held by the author, unless otherwise noted. All rights Reserved.
- Language dc:language
- English
Identifiers
dc:identifier.*- Identifier
-
local-cont-no: submission_4933
ark: ark:/67531/metadc2652443