North Texas State University
Evaluation of Adsorption and Microcoulometric Methods for Determination of Halogenated Organic Compounds in Water
Abstract
dc:descriptionTwo adsorption/microcoulometric methods have been investigated for total organic halogen (TOX) in water. TOX, a proposed water-quality parameter, is a rapid, surrogate method to detect halides microcoulometrically and does not require compound identification before water quality can be judged. An XAD resin is used to concentrate organic halides that are eluted by a two-step, two-solvent procedure, followed by analysis using :chromatography or pyrolysis to convert organic halides to halide. In the granular activated carbon (GAC) method, the entire GAC-organic halide sample is pyrolyzed. TOX measurements of model compounds are comparable by both methods, but GAC was found to be superior to XAD for adsorption of chlorinated humics in drinking water and chlorinated lake water.
Degree
thesis:*- Grantor dc:publisher
- North Texas State University
- Year dc:date
- 1980
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Kinstley, Warren O. (Warren Owen)
- Contributors dc:contributor
-
- Glaze, William
- Daugherty, Kenneth E.
- Marshall, James L., 1940-
Subjects
dc:subject × 6Rights
dc:rights- Statement dc:rights
-
- Public
- Kinstley, Warren O. (Warren Owen)
- Copyright
- Copyright is held by the author, unless otherwise noted. All rights reserved.
- Language dc:language
- English
Identifiers
dc:identifier.*- Identifier
-
local-cont-no: 1002776143-Kinstley
call-no: 379 N81 no.5688
untcat: b1203771
oclc: 7153172