Back to search

University of North Texas

Automated Low-cost Instrument for Measuring Total Column Ozone

Abstract

dc:description

Networks of ground-based and satellite borne instruments to measure ultraviolet (UV) sunlight and total column ozone have greatly contributed to an understanding of increased amounts of UV reaching the surface of the Earth caused by stratospheric ozone depletion. Increased UV radiation has important potential effects on human health, and agricultural and ecological systems. Observations from these networks make it possible to monitor total ozone decreases and to predict ozone recovery trends due to global efforts to curb the use of products releasing chemicals harmful to the ozone layer. Thus, continued and expanded global monitoring of ozone and UV is needed. However, existing automatic stratospheric ozone monitors are complex and expensive instruments. The main objective of this research was the development of a low-cost fully automated total column ozone monitoring instrument which, because of its affordability, will increase the number of instruments available for ground-based observations. The new instrument is based on a high-resolution fiber optic spectrometer, coupled with fiber optics that are precisely aimed by a pan and tilt positioning mechanism and with controlling programs written in commonly available software platforms which run on a personal computer. This project makes use of novel low-cost fiber optic spectrometer technology. A cost advantage is gained over available units by placing one end of the fiber outdoors to collect sunlight and convey it indoors, thereby allowing the spectrometer and computer to be placed in a controlled environment. This reduces the cost of weatherproofing and thermal compensation. Cost savings also result from a simplified sun targeting system, because only a small pan and tilt device is required to aim the lightweight fiber optic ends. Precision sun-targeting algorithms, optical filter selection, and software to derive ozone from spectral measurements by the spectrometer are a major contribution of this project. This system is a flexible platform which may be adapted to study other atmospheric constituents such as sulfur dioxide, nitrous oxides, and haze.

Degree

thesis:*
Grantor dc:publisher
University of North Texas
Year dc:date
2006

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Nebgen, Gilbert Bernard
Contributors dc:contributor
  • Acevedo, Miguel F.
  • Atkinson, Samuel F.
  • Dickson, Kenneth L.
  • Hudak, Paul F.
  • Waller, William T.

Subjects

dc:subject × 7

Rights

dc:rights
Statement dc:rights
  • Use restricted to UNT Community
  • Copyright
  • Nebgen, Gilbert Bernard
  • Copyright is held by the author, unless otherwise noted. All rights reserved.
Language dc:language
English

Identifiers

dc:identifier.*
Identifier
oclc: 235947540
https://digital.library.unt.edu/ark:/67531/metadc5792/
ark: ark:/67531/metadc5792

Chain of custody

source
Harvested from
University of North Texas
Base URL
digital.library.unt.edu/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Nebgen, Gilbert Bernard. Automated Low-cost Instrument for Measuring Total Column Ozone. University of North Texas, 2006. https://doi.org/10.12794/metadc5792