Construction and Testing of a Charging System and a Corona Column for an Electrostatic Accelerator
Abstract
dc:descriptionThe purpose of the project described in this paper has been to complete construction and to determine the operating characteristics of a charging system and a corona-type controlled leakage system for the compact Van de Graaf generator now under construction at North Texas State University. Calibration data of the generating voltmeter to be used for determining the potential developed by the generator are also included in the paper.