University of North Texas
Analyze and Rebuild an Apparatus to Gauge Evaporative Cooling Effectiveness of Micro-Porous Barriers.
Abstract
dc:descriptionThe sample used for evaporative cooling system is Fabric defender 750 with Shelltite finish. From the experimental data and equations we have diffusion coefficient of 20.9 ± 3.71 x 10-6 m2/s for fabric with one layer with 17%-20% fluctuations from the theory, 27.8 ± 4.5 x 10-6 m2/s for fabric with two layers with 6%-14% fluctuations from the theory and 24.9 ± 4.1 x 10-6 m2/s for fabric with three layers with 13%-16% fluctuations from the theory. Since the thickness of the fabric increases so the mass transport rate decreases so the mass transport resistance should be increases. The intrinsic mass resistances of Fabri-1L, Fabri-2L and Fabri-3L are respectively 104 ± 10.2 s/m, 154 ± 23 s/m and 206 ± 26 s/m from the experiment.
Degree
thesis:*- Grantor dc:publisher
- University of North Texas
- Year dc:date
- 2008
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Mohiti Asli, Ali
- Contributors dc:contributor
-
- Traum, Matthew J.
- Boetcher, Sandra K.S.
- Mirshams, Reza A.
Subjects
dc:subject × 6Rights
dc:rights- Statement dc:rights
-
- Public
- Copyright
- Mohiti Asli, Ali
- Copyright is held by the author, unless otherwise noted. All rights reserved.
- Language dc:language
- English
Identifiers
dc:identifier.*- Identifier
-
oclc: 439699248
https://digital.library.unt.edu/ark:/67531/metadc9750/
ark: ark:/67531/metadc9750