Back to search

University of North Texas

Development of a Real-time Pcr Assay for the Detection of Campylobacter Jejuni and Campylobacter Coli.

Abstract

dc:description

Campylobacter organisms are the most commonly reported bacterial causes of foodborne infection in the world, with Campylobacter jejuni and Campylobacter coli responsible for over 99% of reported infections. Traditionally, Campylobacter species detection is an arduous process, requiring a special incubation environment as well as specific growth media for an extended growth period. The development of a rapid and reliable diagnostic tool for the detection of Campylobacter species would be a valuable aid to the medical diagnostic decision process, especially to rule out Campylobacter infection during the enteric pre-surgical time period. Improved patient outcomes would result if this rapid assay could reduce the number of enteric surgeries. Assays performed during this dissertation project have demonstrated that both SYBR® green and hydrolysis probe assays targeting an 84 nucleotide portion of cadF, a fibronectin-binding gene of Campylobacter jejuni and Campylobacter coli, were able to detect from 101 to 108 copies of organism from stool specimens, did not detect nonspecific targets, and exhibited a coefficient of variation (CV) of 1.1% or less. Analytical validation of sensitivity, specificity and precision, successfully performed in these studies, warrants additional clinical validation of these assays.

Degree

thesis:*
Grantor dc:publisher
University of North Texas
Year dc:date
2009

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Lewis, Sally
Contributors dc:contributor
  • O'Donovan, Gerard
  • Benjamin, Robert C.
  • Knesek, John
  • Meixner, J. Andrew
  • Goven, Art

Subjects

dc:subject × 6

Rights

dc:rights
Statement dc:rights
  • Public
  • Copyright
  • Lewis, Sally
  • Copyright is held by the author, unless otherwise noted. All rights reserved.
Language dc:language
English

Identifiers

dc:identifier.*
Identifier
oclc: 451013587
untcat: b3795639
https://digital.library.unt.edu/ark:/67531/metadc9840/
ark: ark:/67531/metadc9840

Chain of custody

source
Harvested from
University of North Texas
Base URL
digital.library.unt.edu/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Lewis, Sally. Development of a Real-time Pcr Assay for the Detection of Campylobacter Jejuni and Campylobacter Coli.. University of North Texas, 2009. https://doi.org/10.12794/metadc9840