Abstract
dc:descriptionIn forensics and nuclear-forensics, the current lab-based analytical technique employed can be laborious, time consuming, and less suitable for in-situ and real time screening. However, it is important to develop fast and fieldable instrumental technique, without a tradeoff for its high throughput, for drug screening and radionuclear analysis. The underlying factors to be considered in the instrument development ranges from: high potency of samples, even at very low concentration; complex nature of samples in the surrounding environment; real-time chemical composition variation; and instrument size, weight and power (SWAP) consideration. Differential mobility spectrometry (DMS), also known as field asymmetric waveform ion mobility spectrometry (FAIMS), had been a promising rapid gas-phase separation technique, deployable for field applications. Ionized samples are separated and characterized based on their nonlinear motion of their gases under the influence of a differential high and low electric field at or near atmospheric pressure. The implementation of DMS in this study is divided into three parts: (1) Direct analysis in real time (DART) ionization was employed as a robust solvent-less ionization technique, coupled to DMS to demonstrate their combined utility and compatibility. Herein, amphetamine and derivatives were analyzed suggesting a promising alternative for rapid separation and characterization of new psychoactive substances. (2) Flowing atmospheric-pressure afterglow (FAPA) desorption/ionization source was coupled with DMS for the first time for metal-ion speciation. The FAPA-DMS hybrid was used for separation and detection of individual ionic species from cobalt and nickel complexes with acetylacetonate in standard mixtures. (3) Using nano-electrospray source, DMS was coupled to a linear ion trap MS for pre-filtration of uranyl ion from fission products analogue. Subsequently, isotopic measurement was conducted on the uranyl ion. The 235U/238U ratio measured correlate with the result obtained from certified reference material (CRM) of natural uranium, employed in this study.
Degree
thesis:*- Name thesis:degree_name
- Doctor of Philosophy (Ph.D.)
- Level thesis:degree_level
- Dissertation
- Discipline thesis:degree_discipline
- Chemistry
- Grantor
- University of South Florida
- Year dc:date
- 2020
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Ayodeji, Ifeoluwa
- Contributors dc:contributor
-
- Theresa Evans-Nguyen, Ph.D.
- Andreas Muller, Ph.D.
- Abdul Malik, Ph.D.
- Xiaopeng Li, Ph.D.
Subjects
dc:subject × 7Identifiers
dc:identifier.*- Repository record dc:identifier
- https://digitalcommons.usf.edu/etd/8918