Back to search

University of South Florida

Arterial Perfusion Detection Method By Synchronous Detection

Abstract

dc:description

The pressure ulcer is a well-known clinical problem that has plagued many patients in acute-care hospitals and chronic-care facilities. The pressure ulcer has the potential to diminish the quality of a patient's life by hindering the person's physical and emotional well-being. In addition, pressure ulcers are a high-cost problem. Past studies have shown that costs related to the treatment of pressure ulcers have reached 1.335 billion dollars a year in the United States alone. A pressure ulcer is defined as a lesion created by unrelieved pressure, which causes tissue ischemia and subsequently damages the underlying tissue. This sequence of events is mainly centered on ischemia. Ischemia is a condition created by an insufficient flow of blood to an organ or part of an organ such as the skin. The outcome of ischemia is cell death at the tissue level, which is commonly termed necrosis. In the past, researchers employed several different non-invasive techniques in order to detect changes in the condition of human skin when blood flow was restricted. The two most commonly used practices were Laser Doppler Velocimetry and Continuous Wave Ultrasound. Laser Doppler Velocimeter is used to measure cutaneous blood flow in a study region. The moving red blood cells in blood vessels cause a Doppler shift of incident laser light, which correlates with the velocity of blood flow. Continuous Wave Ultrasound involves an ultrasound signal, which is transmitted into the skin. The change in frequency of the reflected signal with respect to the transmitted signal provides an indication of blow flow. The objective of this research was to examine a method for the detection of arterial blood flow, which utilized the 4-electrode sensor for the measurement of Tissue Impedance or the Bio-impedance method. The system developed, for the synchronous detection method, consisted of both analog hardware and software tools. The analog hardware utilized synchronous detection. The software monitored and performed mathematical operations on the retrieved data. The system developed during this research demonstrated the ability to measure the pulsatile impedance of the skin and present the results in a fashion useful to healthcare providers.

Degree

thesis:*
Level thesis:degree_level
Thesis
Discipline thesis:degree_discipline
Electrical Engineering
Grantor
University of South Florida
Year dc:date
2005

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Prevot, Yohan
Contributors dc:contributor
  • Wilfrido Moreno, Ph.D.
  • Jeffrey Harrow, Ph.D.
  • James T. Leffew, Ph.D.
  • Paris Wiley, Ph.D.
  • Horace Gordon, M.S.E.E.

Subjects

dc:subject × 7

Rights

Language dc:language
EN-US

Identifiers

dc:identifier.*
Repository record dc:identifier
https://digitalcommons.usf.edu/etd/823

Chain of custody

source
Harvested from
University of South Florida
Base URL
digitalcommons.usf.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Prevot, Yohan. Arterial Perfusion Detection Method By Synchronous Detection. Thesis thesis, University of South Florida, 2005. https://digitalcommons.usf.edu/etd/823