Back to search

University of South Florida

Long Term Corrosion of Reinforcing Strips in Mechanically Stabilized Earth Walls

Abstract

dc:description

Mechanically stabilized earth (MSE) walls are a more advanced form of a retaining wall, often larger and able to hold back more backfill. This is achieved by reinforcing strips or meshes (most often galvanized steel) placed into the soil, which are held in place by friction. The strips mechanically stabilize the earth while undergoing tension. The wall is covered with concrete medallions that connect to the reinforcements. The medallions have only a secondary structural role in holding up the wall but provide cover that protects the soil from washing away. MSE walls are structures expected to have very long service lives (e.g. 100 years). Confirmation is needed that such durability can be achieved, especially to show that the progression of corrosion of the reinforcement is slow enough. Ten MSE walls around Florida were instrumented (electrical connections were made through the concrete covers to the buried elements) between 1996- 1998 and used to survey corrosion rates of galvanized strip or mesh soil reinforcements. Initial estimates of corrosion-related durability were obtained at that time, indicating a good prognosis for long term durability. The objective of the research in this thesis was to obtain additional indications of the durability of reinforcements in MSE walls in Florida so as to perform a more reliable projection of future performance. Corrosion behavior was measured at the same locations as the initial survey by electrochemical nondestructive tests and by destructive tests. The nondestructive testing consisted of half-cell potentials, polarization resistance measurements, and electrochemical impedance spectroscopy. Corrosion rates reported in this thesis are based upon polarization resistance measurements. The destructive testing consisted of soil extraction and hardware extraction. Hardware extraction enabled independent verification of estimates of electrochemical corrosion rate. Analysis of extracted soil verified that soil composition was within construction specifications. The data from the current survey were also used to further improve prediction of corrosion. The present series of evaluations confirm that the structures are performing as desired based upon the updated model projection of future corrosion.

Degree

thesis:*
Level thesis:degree_level
Thesis
Discipline thesis:degree_discipline
Civil Engineering
Grantor
University of South Florida
Year dc:date
2009

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Berke, Brandon Seth
Contributors dc:contributor
  • Alberto A. Sagüés, Ph.D.
  • Jeffrey Cunningham, Ph.D.
  • A. Gray Mullins, Ph.D.

Subjects

dc:subject × 7

Rights

Language dc:language
EN-US

Identifiers

dc:identifier.*
Repository record dc:identifier
https://digitalcommons.usf.edu/etd/1854

Chain of custody

source
Harvested from
University of South Florida
Base URL
digitalcommons.usf.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Berke, Brandon Seth. Long Term Corrosion of Reinforcing Strips in Mechanically Stabilized Earth Walls. Thesis thesis, University of South Florida, 2009. https://digitalcommons.usf.edu/etd/1854