Back to search

University of South Florida

Numerical Modeling and Simulation for Analysis of Convective Heat and Mass Transfer in Cryogenic Liquid Storage and HVAC&R Applications

Abstract

dc:description

This work presents the use of numerical modeling and simulation for the analysis of transport phenomena in engineering systems including zero boil-off (ZBO) cryogenic storage tanks for liquid hydrogen, refrigerated warehouses, and human-occupied air-conditioned spaces. Seven problems of medium large spaces in these fields are presented. Numerical models were developed and used for the simulation of fluid flow and heat and mass transfer for these problems. Governing equations representing the conservation of mass, momentum, and energy were solved numerically resulting in the solution of velocity, pressure, temperature, and species concentration(s). Numerical solutions were presented as 2-D and 3-D plots that provide more insightful understanding of the relevant transport phenomena. Parametric studies on geometric dimensions and/or boundary conditions were carried out. Four designs of ZBO cryogenic liquid hydrogen storage tank were studied for their thermal performance under heat leak from the surroundings. Steady state analyses show that higher flow rate of forced fluid flow yields lower maximum fluid temperature. 3-D simulation provides the visualization of the complex structures of the 3-D distributions of the fluid velocity and temperature. Transient analysis results in the patterns of fluid velocity and temperature for various stages of a proposed cooling cycle and the prediction of its effective operating term. A typical refrigerated warehouse with a set of ceiling type cooling units were modeled and simulated with both 2-D and 3-D models. It was found that if the cooling units are closer to the stacks of stored packages, lower and more uniform temperature distribution can be achieved. The enhancement of thermal comfort in an air-conditioned residential room by using a ceiling fan was studied and quantified to show that thermal comfort at higher temperature can be improved with the use of ceiling fan. A 3-D model was used for an analysis of thermal comfort and contaminant removal in a hospital operating room. It was found that if the wall supply grilles are closer to the center, the system has better performance in both contaminant removal and thermal comfort. A practical guideline for using CFD modeling in indoor spaces with an effective meshing approach is also proposed.

Degree

thesis:*
Level thesis:degree_level
Dissertation
Discipline thesis:degree_discipline
Mechanical Engineering
Grantor
University of South Florida
Year dc:date
2007

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Ho, Son Hong
Contributors dc:contributor
  • Muhammad M. Rahman, Ph.D.
  • Luis Rosario, Ph.D.
  • Frank Pyrtle, III, Ph.D.
  • Mahmood H. Nachabe, Ph.D.
  • Amy L. Stuart, Ph.D.

Subjects

dc:subject × 8

Rights

Language dc:language
EN-US

Identifiers

dc:identifier.*
Repository record dc:identifier
https://digitalcommons.usf.edu/etd/2215

Chain of custody

source
Harvested from
University of South Florida
Base URL
digitalcommons.usf.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Ho, Son Hong. Numerical Modeling and Simulation for Analysis of Convective Heat and Mass Transfer in Cryogenic Liquid Storage and HVAC&R Applications. Dissertation thesis, University of South Florida, 2007. https://digitalcommons.usf.edu/etd/2215