Back to search

University of South Florida

Underwater FRP Repair of Corrosion Damaged Prestressed Piles

Abstract

dc:description

The goal of the dissertation was to quantify the role of FRP in repairing corroded prestressed piles in a marine environment and to demonstrate the feasibility of using it for field repairs. Three laboratory studies and two field demonstration projects were undertaken to meet this goal.In the first study, corroded specimens were repaired under water and tests conducted to determine the extent of strength retained immediately after wrapping and after further accelerated corrosion. Results showed that the underwater wrap was effective in restoring and maintaining lost capacity in both situations.The second study attempted to determine the effectiveness of FRP for specimens where corrosion had initiated but with no visible signs of distress. In the study, 22 one-third scale model of prestressed piles fabricated with cast-in-chlorides were wrapped at 28 days and exposed to simulated tidal cycles outdoors for nearly three years. Two materials -- carbon and glass were evaluated and the number of layers varied from 1 to 4. Results of gravimteric tests showed that the metal loss in FRP wrapped specimens was about a quarter of that in identical unwrapped controls indicating its effectiveness in this application.The third study attempted to identify the most suitable pre-wrap repair. For this purpose, 26 scale model prestressed specimens were first corroded to a targeted metal loss of 25%, repaired and then exposed to simulated hot salt water tidal cycles for over two years. Two disparate types of repairs were evaluated -- an elaborate full repair and a simpler epoxy injection repair. Results of ultimate and gravimetric tests conducted at the end of the exposure showed that the performance of the full and epoxy injection repairs were comparable but vastly superior compared to identical unwrapped controls.Two field studies were conducted in which full-sized corroding piles were instrumented and wrapped to monitor post-wrap performance. Corrosion rate measurements indicated that rates were lower for wrapped piles compared to identical unwrapped piles. Overall, the study demonstrated that underwater wrapping of piles using FRP is viable and a potentially cost effective method of pile repair in a marine environment.

Degree

thesis:*
Level thesis:degree_level
Dissertation
Discipline thesis:degree_discipline
Civil Engineering
Grantor
University of South Florida
Year dc:date
2006

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Suh, Kwangsuk
Contributors dc:contributor
  • Rajan Sen, Ph.D.
  • A. Gray Mullins, Ph.D.
  • William C. Carpenter, Ph.D.
  • Autar K. Kaw, Ph.D.
  • Kandethody M. Ramachandran, Ph.D.

Subjects

dc:subject × 8

Rights

Language dc:language
EN-US

Identifiers

dc:identifier.*
Repository record dc:identifier
https://digitalcommons.usf.edu/etd/2717

Chain of custody

source
Harvested from
University of South Florida
Base URL
digitalcommons.usf.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Suh, Kwangsuk. Underwater FRP Repair of Corrosion Damaged Prestressed Piles. Dissertation thesis, University of South Florida, 2006. https://digitalcommons.usf.edu/etd/2717