Back to search

University of South Florida

Heat Stress Evaluation of Protective Clothing Ensembles

Abstract

dc:description

Clothing directly affects the level of heat stress exposure. Useful measures to express the thermal characteristics are WBGT (wet bulb globe temperature) clothing adjustment factor (CAF) or apparent total evaporative resistance (Re,T,a). The CAF is assigned through laboratory wear trials following a heat stress protocol in which the air temperature and humidity are progressively increased until the participant clearly loses the ability to maintain thermal equilibrium. The critical condition is the point of thermal transition and from these conditions both the CAF and Re,T,a are computed. The first objective of this study is to compare the thermal characteristics of a coverall made from a prototype fabric to work clothes and a commercial limited-use coverall using CAF and Re,T,a. A second objective is to demonstrate that the Re,T,a of work clothes is the same for progressive or steady-state heat stress protocols. Five participants (4 men and 1 woman) walked on a treadmill at 1.25 m/s at an average metabolic rate of 175 W/m2. Each participant completed at least one progressive heat stress protocols in work clothes, Tyvek® 1422A coveralls [Tyvek® is a registered trademark of DuPont], and a developmental nonwoven polyolefin prototype ensemble provided by DuPont. In addition, four participants completed steady-state protocol in work clothes. Participants did not complete an acclimation period prior to the trials and each trail was separated by at least 40 hours. There are no within participant differences in metabolic rate among ensembles and protocols. There are no differences between the critical WBGT in the current participants and previously acclimatized participants from other studies suggesting that the participants responded as if they were acclimatized. Based on a mixed effects model, there are significant differences between work clothes and Tyvek® 1422A for Re,T,a (0.0103 and 0.0141 m2/W kPa, respectively) and critical WBGT. The CAF for Tyvek is 2.3 °C-WBGT. For the DuPont prototype ensemble, the apparent total evaporative resistance is 0.013 m2kPa/W and the CAF is 0.5 °C. The prototype ensemble shows no difference from work clothes or Tyvek® 1422A in critical WBGT and no difference from work clothes in Re,T,a. Overall, the prototype coveralls exhibited thermal characteristics that would have a lower level of heat stress than the Tyvek 1422A and not significantly different from work clothes. The values for Re,T,a for work clothes were not different between the steady state and progressive protocols. The steady-state protocol near the critical condition can be used for determination of Re,T,a. This opens up the possibility of estimating Re,T,a from studies that do not use the progressive protocol.

Degree

thesis:*
Level thesis:degree_level
Thesis
Discipline thesis:degree_discipline
Environmental and Occupational Health
Grantor
University of South Florida
Year dc:date
2010

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Pease, Amanda Lee
Contributors dc:contributor
  • Thomas E. Bernard, Ph.D.
  • Candi Ashley, Ph.D.
  • Steven Mlynarek, Ph.D.

Subjects

dc:subject × 10

Rights

Language dc:language
EN-US

Identifiers

dc:identifier.*
Repository record dc:identifier
https://digitalcommons.usf.edu/etd/3485

Chain of custody

source
Harvested from
University of South Florida
Base URL
digitalcommons.usf.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Pease, Amanda Lee. Heat Stress Evaluation of Protective Clothing Ensembles. Thesis thesis, University of South Florida, 2010. https://digitalcommons.usf.edu/etd/3485