Back to search

Hosted by Utah State University Libraries

TRISO Fuel Compact Thermal Conductivity Measurement Instrument Development

Abstract

dc:description.abstract

Thermal conductivity is an important thermophysical property needed for effectively predicting fuel performance. As part of the Next Generation Nuclear Plant (NGNP) program, the thermal conductivity of tri-isotropic (TRISO) fuel needs to be measured over a temperature range characteristic of its usage. The composite nature of TRISO fuel requires that measurement be performed over the entire length of the compact in a non-destructive manner. No existing measurement system is capable of performing such a measurement. A measurement system has been designed based on the steady-state, guarded-comparative-longitudinal heat flow technique. The system as currently designed is capable of measuring cylindrical samples with diameters ~12.3-mm (~0.5″) with lengths ~25-mm (~1″). The system is currently operable in a temperature range of 400 K to 1100 K for materials with thermal conductivities on the order of 10 W/m/K to 70 W/m/K. The system has been designed, built, and tested. An uncertainty analysis for the determinate errors of the system has been performed finding a result of 5.5%. Finite element modeling of the system measurement method has also been accomplished demonstrating optimal design, operating conditions, and associated bias error. Measurements have been performed on three calibration/validation materials: SS304, 99.95% pure iron, and inconel 625. In addition, NGNP graphite with ZrO2 particles and NGNP AGR-2 graphite matrix only, both in compact form, have been measured. Results from the SS304 sample show agreement of better than 3% for a 300–600°C temperature range. For iron between 100–600°C, the difference with published values is < 8% for all temperatures. The maximum difference from published data for inconel 625 is 5.8%, near 600°C. Both NGNP samples were measured from 100–800°C. All results are presented and discussed. Finally, a discussion of ongoing work is included as well as a brief discussion of implementation under other operating conditions, including higher temperatures and adaptation for use in a glovebox or hot cell.

Degree

thesis:*
Name thesis:degree_name
Master of Science (MS)
Level thesis:degree_level
Thesis
Discipline thesis:degree_discipline
Mechanical and Aerospace Engineering
Grantor dc:publisher
Hosted by Utah State University Libraries

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Jensen, Colby
Contributors dc:contributor
  • Heng Ban
  • Byard Wood
  • Leijun Li

Subjects

dc:subject × 6

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Utah State University
Base URL
digitalcommons.usu.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Jensen, Colby. TRISO Fuel Compact Thermal Conductivity Measurement Instrument Development. Thesis thesis, Hosted by Utah State University Libraries, https://digitalcommons.usu.edu/etd/838