Abstract

dc:description.abstract

Particle image velocimetry (PIV) is used to make volume-flow-rate measurements at the exit of a turbulent, planar nozzle. The objective of this report is to assess a range of data acquisition and processing parameters. Data is acquired for volume flow rates of Reynolds numbers between 10,000 and 100,000 for both two-component (2C) and stereo PIV. The parameters are systematically changed one at a time and evaluated using differences in uncertainty, calculation time, and volume- flow-rate deviation. Data acquisition parameters follow the trends of previous work. A multitude of processing parameters were varied for several PIV processing methods. Recommendations for each method are developed and listed with potential drawbacks. 2C PIV was found to underestimate volume-flow-rate by 3-4% depending on the integration scheme and stereo PIV underestimated volume-flow-rate by 2%.

Degree

thesis:*
Name thesis:degree_name
Master of Science (MS)
Level thesis:degree_level
Thesis
Discipline thesis:degree_discipline
Mechanical and Aerospace Engineering
Grantor dc:publisher
Hosted by Utah State University Libraries

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Cressall, Rick
Contributors dc:contributor
  • Barton Smith
  • Ryan Berke
  • Tadd Truscott

Subjects

dc:subject × 5

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Utah State University
Base URL
digitalcommons.usu.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Cressall, Rick. Best Practices for Volume Flow Rate Measurements Using PIV at the Exit of a Turbulent Planar Jet. Thesis thesis, Hosted by Utah State University Libraries, https://digitalcommons.usu.edu/etd/5218