Back to search

Hosted by Utah State University Libraries

Rapid Determination of Milk Components and Detection of Adulteration Using Fourier Transform Infrared Technology

Abstract

dc:description.abstract

Absorption bands responding to changes in fat, protein, and lactose concentrations in milk were determined. The effects of milk fat variation and lipolysis on the infrared spectrum were studied. Absorbances from 1283 to 1100 cm-1 correlated with fat, protein, and lactose concentration and showed a low response to milk fat variation and lipolysis. A Fourier transform infrared spectrometer equipped with an attenuated total internal reflectance cell was calibrated using these absorption band s, partial least squares statistics, and milk samples from herds in Minnesota. When the fat, protein, and lactose concentrations in these samples were predicted, the standard deviations of difference (reference - infrared) were .22, .06, and .02%. When the fat, protein, and lactose concentrations in a separate set of samples from herds in California were predicted, the standard deviations of difference were 1.23, .10, and .07%. Substitution of a 15 μm pathlength transmission cell for the attenuated total internal reflectance cell changed the standard deviations of difference to .07, .11, and .06% in the calibration (Minnesota) samples and .09, .10, and .16% in the validation (California) samples. Infrared spectroscopy was used to measure whey powder in an adulterated sample of nonfat dry milk. Mixtures of nonfat dry milk containing whey powder at various concentrations were analyzed using absorption bands between 1400 and 1200 cm-1 in the infrared spectrum. There was a strong correlation (r > .99) between predicted and measured concentrations of whey powder in adulterated samples. Accuracy was not affected by processing conditions, source of nonfat dry milk, and origin of whey powder. A rapid method for detecting soybean oil in process cheese was developed. The infrared spectrum of each sample was collected using an accessory designed for analysis of solid samples. A linear relationship fit (= .98) when the ratio of absorbance at 2957 and 2852 cm-1 was plotted versus percent adulteration.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy (PhD)
Level thesis:degree_level
Dissertation
Discipline thesis:degree_discipline
Nutrition, Dietetics, and Food Sciences
Grantor dc:publisher
Hosted by Utah State University Libraries

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Mendenhall, Ivan Von
Contributors dc:contributor
  • Rodney J. Brown
  • Donald J. McMahon
  • Donald V. Sisson

Subjects

dc:subject × 6

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Utah State University
Base URL
digitalcommons.usu.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Mendenhall, Ivan Von. Rapid Determination of Milk Components and Detection of Adulteration Using Fourier Transform Infrared Technology. Dissertation thesis, Hosted by Utah State University Libraries, https://digitalcommons.usu.edu/etd/5367