Back to search

Hosted by Utah State University Libraries

Influence of Ultra-High Temperature Process Parameters on Age Gelation of Mille Concentrate

Abstract

dc:description.abstract

The purpose of this research was to investigate the effect of ultra-high temperature process parameters on age gelation of milk concentrate. Skim milk was concentrated to 2X (volume reduction) using reverse osmosis. The milk concentrate was preheated at 75 or 90°C for 20 or 50 s and UHT-processed at 138 or 145°C for 4 or 16 s. Sterilizing methods used were direct steam injection and indirect plate heat exchanger. The samples were aseptically collected in presterilized plastic containers and stored at 15 or 35°C. At 15°C storage temperature, the steam-injected samples gelled in 5 months when 4 s UHT time was used. When UHT time was increased to 16 s, the samples gelled in 6 months. Of the samples that were UHT processed by indirect plate heat exchanger for 4 s and stored at 15°C, all gelled after 7 months. When UHT time was increased to 16 s, all the 138°C samples gelled after 7 months as did the samples that were preheated for 50 s and UHT-processed at 138°C. The samples preheated at 75°C for 50 sand UHT-processed at 145°C gelled after 8 months, whereas at 90°C preheat temperature the samples gelled after 9 months. The samples stored at 35°C did not gel but showed different sedimentation levels. The sediment depth in the container was always greater for the steam-injected samples. The samples that received higher heat treatments by the two processing methods had a higher sedimentation depth. The pH decreased during storage and the extent of reduction was higher at 35°C storage temperature. Maillard browning occurred at both storage temperatures. Browning was greater in samples stored at 35°C and processed by indirect plate heat exchanger.

Degree

thesis:*
Name thesis:degree_name
Master of Science (MS)
Level thesis:degree_level
Thesis
Discipline thesis:degree_discipline
Nutrition, Dietetics, and Food Sciences
Grantor dc:publisher
Hosted by Utah State University Libraries

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Elhilaly, Mohamed A.
Contributors dc:contributor
  • Donald J. McMahon
  • C. L. Hansen
  • P. A. Savello

Subjects

dc:subject × 6

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Utah State University
Base URL
digitalcommons.usu.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Elhilaly, Mohamed A.. Influence of Ultra-High Temperature Process Parameters on Age Gelation of Mille Concentrate. Thesis thesis, Hosted by Utah State University Libraries, https://digitalcommons.usu.edu/etd/5412