Abstract
dc:description.abstractPhysical data was collected for a 6-in. long-radius elbow meter in order to determine the effects of certain upstream disturbances on its metering performance. Discharge coefficients are calculated for each of the three tested configurations at various installation distances between the upstream disturbance and the elbow meter. Computational Fluid Dynamics (CFD) software was used to determine which turbulence models most accurately modeled the observed physical results in order to provide a base from which to model the effects of additional upstream disturbances not modeled in this study.
Degree
thesis:*- Name thesis:degree_name
- Master of Science (MS)
- Level thesis:degree_level
- Thesis
- Discipline thesis:degree_discipline
- Civil and Environmental Engineering
- Grantor dc:publisher
- Hosted by Utah State University Libraries
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Manwaring, Riley D.
- Contributors dc:contributor
-
- Michael C. Johnson
- Zachary B. Sharp