dc:description.abstract

In order to monitor virus levels in most water systems, a virus concentration step is necessary for current assay systems to detect the presence of the virus. Microscopic fluorescent particles were used to determine the efficiency of a microflotation apparatus developed for use in a virus concentration method. The adsorption of particles or viruses onto bubbles in water, enhanced by added or natural foaming agents, is the governing principle of the concentration method investigated. Tests were conducted with organic fluorescent particles in distilled water containing different foaming agents: skim milk, protease peptone, yeast extract, and polyethylene glycol 20M. Tests were conducted to deter mine the effects of pH 5 vs. 9, sparging disc pore size of 160 vs. 240 micrometers, and foaming agent concentration on effciency of the microflotation apparatus to concentrate the fluorescent particles. Tests were also conducted with fluorescent particles in sewage. Concentration factors of greater than 100 were obtained with fluorescent particles both in distilled water and raw sewage. The microflotation system was then tested with reovirus in distilled water and sewage. Some concentration of reovirus was achieved in distilled water with added foaming agent. Concentration factors of greater than 100 were obtained in tests with reovirus in sewage without the addition of foaming agents. The microflotation system developed in this research concentrated fluorescent particles as well as reovirus from raw sewage samples at concentration factors which represented a 100-fold increase in the collected sample concentration over that of the bulk water sampled. The potential hazard of bioaerosol formation through the vacuum pump-operated collection system was found to be insignificant. Concentration of Bacillus subtilis var. niger, commonly known as BG, was also achieved with a concentration factor averaging 45.

Degree

thesis:*
Name thesis:degree_name
Master of Science (MS)
Level thesis:degree_level
Thesis
Discipline thesis:degree_discipline
Biology

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Marton, Daniel Dalton
Contributors dc:contributor
  • Rex S. Spendlove
  • J. Clifton Spendlove
  • Bill B. Barnett

Subjects

dc:subject × 4

Identifiers

dc:identifier.*
Repository record dc:identifier
https://digitalcommons.usu.edu/etd_biology/505

Chain of custody

source
Harvested from
Utah State University
Base URL
digitalcommons.usu.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Marton, Daniel Dalton. Development of a Microflotation System to Continuously Sample Water for Reovirus Concentration and Detection. Thesis thesis, https://digitalcommons.usu.edu/etd_biology/505