Back to search

Utah State University

An Emergency Transfusion Technique

Abstract

dc:description.abstract

The purpose of this study was to develop a transfusion technique that could be used in developing countries and in times of civilian disaster or wartime, when electricity and sophisticated equipment are not available. This technique consists of the use of a device for direct transfusion, consisting of plastic tubing connected to a stopcock and syringe, and a method of direct compatibility testing. The device was tested on sheep using a flow rate of 1 ml/s. No problems were encountered and no adverse reactions were observed. The compatibility technique was tested on 150 blood specimens. It was able to detect incompatibility or compatibility, in 94 percent of all compatibility tests and in 100 percent of those cases involving ABO incompatibilities, when compared to the standard tube test used in blood banking today.

Degree

thesis:*
Name thesis:degree_name
Master of Science (MS)
Level thesis:degree_level
Thesis
Discipline thesis:degree_discipline
Biology

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Rich, Ann
Contributors dc:contributor
  • David (Andy) Anderson

Subjects

dc:subject × 4

Identifiers

dc:identifier.*
Repository record dc:identifier
https://digitalcommons.usu.edu/etd_biology/544

Chain of custody

source
Harvested from
Utah State University
Base URL
digitalcommons.usu.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Rich, Ann. An Emergency Transfusion Technique. Thesis thesis, https://digitalcommons.usu.edu/etd_biology/544