Abstract
dc:description.abstractThe purpose of this study was to develop a transfusion technique that could be used in developing countries and in times of civilian disaster or wartime, when electricity and sophisticated equipment are not available. This technique consists of the use of a device for direct transfusion, consisting of plastic tubing connected to a stopcock and syringe, and a method of direct compatibility testing. The device was tested on sheep using a flow rate of 1 ml/s. No problems were encountered and no adverse reactions were observed. The compatibility technique was tested on 150 blood specimens. It was able to detect incompatibility or compatibility, in 94 percent of all compatibility tests and in 100 percent of those cases involving ABO incompatibilities, when compared to the standard tube test used in blood banking today.
Degree
thesis:*- Name thesis:degree_name
- Master of Science (MS)
- Level thesis:degree_level
- Thesis
- Discipline thesis:degree_discipline
- Biology
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Rich, Ann
- Contributors dc:contributor
-
- David (Andy) Anderson
Subjects
dc:subject × 4Identifiers
dc:identifier.*- Repository record dc:identifier
- https://digitalcommons.usu.edu/etd_biology/544