Abstract

dc:description.abstract

Magnetic field measurements have been made on a 4" diameter aperture beam-line quadrupole magnet. One method of measurement uses a rotating coil with a narrow bandwidth wave analyzer and the other a Hall plate survey system interfaced to an on-line mini-computer. The measurements are analyzed to yield the pole tip field as a function of the excitation current, the harmonic content of the field both as a function of axial position and of the entire magnet and the effective length of the field. Quadrupole field measurements using a short rotating coil are analyzed to determine the fringe field configuration. Errors in the two methods are considered in detail, including the effect of misalignment of the rotating coil and cross-coupling in the Hall plate.

Degree

thesis:*
Level thesis:degree_level
Master of Science M.Sc.
Department thesis:degree_department
Department of Physics
Year dc:date.issued
1973

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Fyvie, Robert David

Rights

dc:rights
Statement dc:rights
  • Available to the World Wide Web

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1828/17846

Chain of custody

source
Harvested from
University of Victoria (Canada)
Base URL
dspace.library.uvic.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Fyvie, Robert David. Magnetic field measurements in quadrupole magnets. Master of Science M.Sc. thesis, 1973. https://hdl.handle.net/1828/17846