University of Victoria (Canada)
A strategy for sewage network and outflow distribution management to reduce the impact of sewage discharged into tidal waters
Abstract
dc:description.abstractResearch presented in this thesis explores the physical feasibility of reducing the environmental impact of sewage discharged into tidal waters by controlling the times of discharge. Proposed is a sewage outflow control system consisting of holding tanks, located throughout the sewage collection network. The holding tanks are used to restrict outflow to times when the dilution and dispersal characteristics of the receiving water are such that the near shore environmental impact of the discharged sewage is minimized, while simultaneously providing primary treatment. To explore the physical feasibility of such an outflow control system, the East Coast Interceptor and the Clover Point sewage catchment area of Victoria are selected as a case study. For this research it is assumed that the environmental impact of discharged sewage can be minimized by holding sewage during flood tides and releasing it during the following ebb tide. Therefore, based on predicted tidal conditions for the Victoria area, flood/ ebb ratios which describe the relationship between the durations of successive flood and ebb tides are calculated. Using these ratios it is possible to determine how much time is available to release sewage from the outflow control system holding tanks. Sewage flow characteristics and the sewage collection and disposal infrastructure are then examined and evaluated, and a number of potential holding tank configurations are identified. A fill/ flush ratio, which is the ratio between the amount of time required to fill and then flush a given series of holding tanks, is calculated for each potential holding tank configuration. Based on these calculations, it is concluded that the holding tank configuration most likely to be physically feasible consists of tanks located at the Broom Road and George Street connections to the East Coast Interceptor. Examination of this outflow control system configuration under the full range of tidal and sewage flow conditions revealed that the system is physically feasible approximately 80 percent of the time during dry weather sewage flow conditions and approximately 30 percent of the time during wet weather sewage flow conditions. Exploratory research presented in this thesis concludes, therefore, that the proposed outflow control system is feasible. However, operational problems will occur during wet weather sewage flow conditions. In order to conduct this research, a number of assumptions had to be made. It is recommended that a decision support system capable of eliminating these assumptions, and identifying a physically and politically feasible outflow control system holding tank configuration be developed.
Degree
thesis:*- Level thesis:degree_level
- Master of Science M.Sc.
- Department thesis:degree_department
- Department of Geography
- Year dc:date.issued
- 1992
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Gowan, Robert Francis
Subjects
dc:subject × 1Rights
dc:rights- Statement dc:rights
-
- Available to the World Wide Web
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/1828/17937