University of Victoria (Canada)
Cryogenic testing of an electromagnetic actuation system for low temperature slit masks
Abstract
dc:description.abstractThe James Web Space telescope will replace the aging Hubble in 2012. One instrument onboard will be the Near Infrared Spectroscope which will require a reconfigurable slit mask to control light incident upon it. One design for this device is called the Mechanically Actuated Reconfigurable Slit mask (MARS). The MARS uses several electromagnetic clamps to move shutters though the focal plane. The goal of this thesis is to develop a system to characterise these clamps at cryogenic temperatures. FEA simulations predicted clamp performance and aided in the development of a test apparatus. An apparatus which utilises the Lorentz force to force the clamp jaws open was developed, built and tested. The device was built inside a cryostat which operated at 30 K. It was found that the test apparatus performed as intended. The clamps themselves proved to be problematic. Small perturbations or misalignments caused significant inconsistencies in experimental results.
Degree
thesis:*- Level thesis:degree_level
- Master of Applied Science M.A.Sc.
- Department thesis:degree_department
- Department of Mechanical Engineering
- Year dc:date.issued
- 2009
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Francescutti, Paul
- Advisor dc:contributor.supervisor
-
- Rowe, Andrew Michael
Subjects
dc:subject × 4Rights
dc:rights- Statement dc:rights
-
- Available to the World Wide Web
- Language dc:language.iso
- en, English
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- http://hdl.handle.net/1828/1849