Back to search

University of Victoria (Canada)

Modeling and optimization of a gas transmission network for supplying natural gas with hydrogen injection

Abstract

dc:description.abstract

This study focuses on optimizing natural gas transmission pipelines transporting methane-hydrogen mixtures to minimize compressor fuel consumption. The optimization problem employs MATLAB and genetic algorithm for the modeling and optimization of the pipeline. The study targets both single and multi-delivery point pipelines for the optimization. For an 800 km pipeline, the fuel consumption for delivering 8 GW of power is 2.98% for single delivery considering natural gas transmission. Around 2.7% fuel is consumed for multi-delivery pipelines to delivery same power for natural gas considering six delivery points. Introducing hydrogen into the natural gas mixture increases fuel consumption proportionally, with 5-20vol% hydrogen injections resulting in fuel consumptions of 3-3.8%, respectively, for multi-delivery pipelines. Pure hydrogen (100% H2) injection leads to a significant increase in fuel consumption up to 19.9%. The study also explores the impact of maximum allowable operating pressure (MAOP) on pipeline performance. The operating pressure of the pipeline increases with the increasing hydrogen content while maintaining the constant power delivery. This highlights the need for higher pressures to transport hydrogen-enriched natural gas efficiently. Because hydrogen has a lower energy density, mixtures containing it tend to cause a higher pressure to drop when delivering energy at a desired rate leading higher compressor fuel consumption. The study finds that blending hydrogen reduces CO₂ emissions significantly from compressor fuel consumption, with reductions of 1.85-7.25% for 5-20vol% hydrogen injections, respectively. In terms of economic implications, transitioning from natural gas to electric compressors reduces emissions due to compressor fuel consumption from 430 ktCO₂/year to 31.9 ktCO₂/year, albeit with a cost increase for compressor power supply from $15.39 million to $178 million annually. The results underscore the usefulness of the optimization approach in enhancing fuel efficiency and reducing emissions.

Degree

thesis:*
Level thesis:degree_level
Master of Applied Science MASc
Department thesis:degree_department
Department of Mechanical Engineering
Year dc:date.issued
2024

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Das, Pronob
Advisor dc:contributor.supervisor
  • Rowe, Andrew

Subjects

dc:subject × 4

Rights

dc:rights
Statement dc:rights
  • Available to the World Wide Web
Language dc:language.iso
en, English

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1828/18523

Chain of custody

source
Harvested from
University of Victoria (Canada)
Base URL
dspace.library.uvic.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Das, Pronob. Modeling and optimization of a gas transmission network for supplying natural gas with hydrogen injection. Master of Applied Science MASc thesis, 2024. https://hdl.handle.net/1828/18523