Two Open-Path Tunable Diode Laser Absorption Spectrometers were constructed. The first incorporated a 1.60 µm DFB diode laser and was used to establish the calibration procedures for an open-path TDLAS, using CO2 as the target gas. The other, at 1.31 µm and based upon the Short-External-Cavity design, was used to determine the suitability of the 1.31 µm region for measurements of atmospheric water vapor and CH₄. Both systems employed Wavelength Modulation Spectroscopy with second harmonic detection. For the 1.60 µm system, the detection sensitivity over twelve hours, achieved from an indoor measurement equivalent to 355 ppm of CO2 over 475 m was 24x10-6 with a 1 second integration period. This corresponds to a CO2 measurement stability of 0.7%. For a 120 m atmospheric path, the CO2 measurement stability was~ 8 ppm(~ 2%). The figure obtained for the average concentration was found to be dependent upon optical alignment to some extent which gave a measurement range of between 350 and 450 ppm. The origin of this effect is thought to be from etalons between the laser and collimating lens and may be removed by selection of appropriate diode laser optics. Laboratory results from the Short-External-Cavity system were obtained, using low pressure CH₄ as the target gas. Initial measurements confirmed the location of the R(6), R(7) and R(8) absorption lines of the v₂+2v₃ band. Time series data of the R(6) showed a detection sensitivity of 6x10·5 over a half hour period, which was obtained while actively stabilizing the longitudinal mode output of the laser via the use of a scanning monochromator and PC as opposed to more conventional methods using power stabilization. Open-path measurements at optical paths of 120 m and 1 km showed the presence of several strong water vapor absorptions, but no measurements were obtained for CR₄. The R(7) and R(8) regions were free of water vapor absorptions, but the strong R(6) triplet was influenced by the presence of water vapor.

Degree

thesis:*
Level thesis:degree_level
Master of Science M.Sc.
Department thesis:degree_department
School of Earth and Ocean Sciences
Year dc:date.issued
1997

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Landles, William Kennedy

Rights

dc:rights
Statement dc:rights
  • Available to the World Wide Web

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1828/18526

Chain of custody

source
Harvested from
University of Victoria (Canada)
Base URL
dspace.library.uvic.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Landles, William Kennedy. Suitability of a short-external-cavity laser system within an open- path tunable diode laser absorption spectrometer (OP-tdlas). Master of Science M.Sc. thesis, 1997. https://hdl.handle.net/1828/18526