University of Victoria (Canada)
The calculation of flow and heat transfer over surface mounted ribs using a domain decomposition method
Abstract
dc:description.abstractA numerical study of the accuracy and simulated parallel efficiency of domain decomposition applied to a finite volume fluid flow solver is presented. Two test cases were studied, developing flow in a channel and flow over a surface mounted rib, each with several subdomain configurations. Three methods to improve accuracy and convergence rates were investigated. An over relaxation scheme was applied at the subdomain interfaces, a subdomain continuity modification was implemented, and the subdomain calculation sequence was modified. All three methods improved the convergence rate. The subdomain continuity modification was necessary for high aspect ratio subdomain configurations to converge. It was found that solutions calculated with low aspect ratio subdomains produced dimensionless velocity differences from identical single domain solutions on the order of 104 . Parallel efficiencies ranged from 46% to 154%, with efficiency dropping as more domains are added. The domain decomposition method was applied to simulate forced convection cooling of an electronic device. The device was modeled as a rib mounted in a channel. Reynold's number, channel blockage ratio and Prandtl number are varied. Thermal conductivities are varied over a range covering most of the commonly use encapsulents. Conjugate heat transfer is used to model the thermal field produced from the heat generating rib. The flowfield produced at a blockage ratio of 0.50 and a Reynold's number of 150 produced two secondary recirculation zones, one on top of the rib and the other on the upper wall after the rib. The other flowfields only produced recirculation zones in front and behind the rib. The maximum temperature, which is the parameter of interest in design applications, was found to be weakly linked to Reynold 's number blockage ratio and Prandtl number, but for dimensionless thermal conductivity less than 50 the maximum rib temperature is strongly dependent on thermal conductivity. For dimensionless thermal conductivities in excess of approximately 100, this dependency becomes weak.
Degree
thesis:*- Level thesis:degree_level
- Master of Applied Science M.A.Sc.
- Department thesis:degree_department
- Department of Mechanical Engineering
- Year dc:date.issued
- 1993
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Zapach, Trevor George
Subjects
dc:subject × 1Rights
dc:rights- Statement dc:rights
-
- Available to the World Wide Web
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/1828/20261