Back to search

University of Victoria (Canada)

Impacts of curtailment costs on optimal generation and storage capacity

Abstract

dc:description.abstract

This study examines the effects of curtailment costs on cost-minimized energy capacity for Metro Vancouver, focusing on electrification and Renewable Gas (RG) pathways. Using Calliope, we assess the impact of curtailment costs on storage capacity, renewable generation, and system costs. Results show that curtailment costs significantly affect the electrification pathway, driving increased battery storage activity and selective deployment of renewable generation to limit curtailment. In contrast, the RG pathway adjusts only gas storage capacity in response to curtailment costs, relying solely on wind technology as its Variable Renewable Energy source without the need of an electric storage. These findings highlight the importance of tailored curtailment cost strategies for efficient renewable integration, enhancing resilience and cost-effectiveness across energy transition pathways.

Degree

thesis:*
Level thesis:degree_level
Master of Applied Science MASc
Department thesis:degree_department
Department of Mechanical Engineering
Year dc:date.issued
2024

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Herrera Ibarra, Luis Antonio
Advisors dc:contributor.supervisor
  • Rowe, Andrew Michael
  • Wild, Peter Martin

Subjects

dc:subject × 4

Rights

dc:rights
Statement dc:rights
  • Available to the World Wide Web
Language dc:language.iso
en, English

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1828/20970

Chain of custody

source
Harvested from
University of Victoria (Canada)
Base URL
dspace.library.uvic.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Herrera Ibarra, Luis Antonio. Impacts of curtailment costs on optimal generation and storage capacity. Master of Applied Science MASc thesis, 2024. https://hdl.handle.net/1828/20970