Back to search

University of Victoria (Canada)

Microfluidic fabrication of enteric-coated liquid-core ATPS capsules for colon-targeted probiotic delivery

Abstract

dc:description.abstract

Colon-targeted delivery of live probiotics remains challenging because gastric acidity and intestinal bile salts can severely reduce viability, while premature leakage can prevent sufficient dosing at the site of action. This dissertation presents a simplified microfluidic platform for producing enteric-coated, liquid-core, hydrogel-shell capsules for colon delivery. The system generates water-in-water-in-oil (W/W/O) double emulsions using a poly(ethylene glycol) (PEG) and dextran aqueous two-phase system (ATPS) in a flow-focusing device, with improved droplet stability enabled by increasing channel height at the oil junction and avoiding complex surface treatments. The capsule architecture integrates (i) a PEG-based liquid core for high cargo loading, (ii) a dextran/alginate/Ca–ethylenediaminetetraacetic acid (EDTA) shell that is crosslinked on-chip via acid-triggered Ca²⁺ release, and (iii) a layer-by-layer coating of chitosan and Eudragit S100 nanoparticles to provide upper-GI protection and pH-responsive gating. To generate Eudragit S100 nanoparticles, a dedicated microfluidic micromixer was designed for continuous antisolvent nanoprecipitation (acetone→water), enabling rapid, reproducible mixing and supporting uniform enteric coating of the capsules. To explain and control emulsion morphology, we combined volume-of-fluid computational fluid dynamics (CFD) simulations with targeted experiments to quantify necking dynamics and internal recirculation patterns, revealing how shell viscosity and geometric confinement drive the formation of one-core or two-core morphologies. Capsule performance was evaluated under sequential exposure to simulated gastric fluid (SGF, 0–2 h) and simulated intestinal fluid (SIF, 2–6 h). Uncoated capsules showed poor gastric protection, with Escherichia coli Nissle 1917 (EcN) viability decreasing to 62% after 1 h and reaching 0% by 2 h in SGF. In contrast, chitosan-coated capsules maintained high SGF viability (93% at 1 h; 89% at 2 h), while the Eudragit+chitosan multilayer achieved the highest survival (97% at 1 h; 95.2% at 2 h). After transfer to SIF, both coated formulations remained highly protective, with the Eudragit+chitosan capsules sustaining a consistent ~5.9–6.1 percentage-point advantage over chitosan alone from 2–6 h (95.2→93.0% vs 89→87.1%). Functional assays demonstrated strong retention during simulated upper-GI transit, with negligible release in SGF (0–2 h) and low cumulative release (6.7%) after sequential SGF→SIF exposure (0–6 h). Under colon-mimicking conditions with simulated colonic fluid (SCF) containing dextranase, release followed a lag–acceleration–plateau behavior, reaching ~85–90% by ~3–6 h and ~95–100% by ~7–8 h, consistent with enteric dissolution and enzyme-driven shell loosening.

Degree

thesis:*
Level thesis:degree_level
Doctor of Philosophy PhD
Department thesis:degree_department
Department of Mechanical Engineering
Year dc:date.issued
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Yazdani Motlagh, Kaveh
Advisor dc:contributor.supervisor
  • Hoorfar, Mina

Subjects

dc:subject × 7

Rights

dc:rights
Statement dc:rights
  • Available to the World Wide Web
Language dc:language.iso
en, English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
University of Victoria (Canada)
Base URL
dspace.library.uvic.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Yazdani Motlagh, Kaveh. Microfluidic fabrication of enteric-coated liquid-core ATPS capsules for colon-targeted probiotic delivery. Doctor of Philosophy PhD thesis, 2026. https://hdl.handle.net/1828/23756