Back to search

University of Victoria (Canada)

Condensed phase membrane introduction mass spectrometry

Abstract

dc:description.abstract

Over the last few decades, membrane introduction mass spectrometry (MIMS) has been established as a robust tool for the on-line continuous monitoring of trace gases and volatile organic compounds. However, the range of amenable anlaytes has been limited by the need for molecules to pervaporate into a gaseous acceptor phase, or high vacuum environment of a mass spectrometer. This thesis expands the range of amenable analytes for MIMS to include larger, less volatile molecules (e.g., 200 to 500 Da), such as pharmaceuticals, persistent organic pollutants, and small biomolecules. This was achieved through the use of a liquid|membrane|liquid interface. We distinguish the technique from conventional MIMS, which uses a gaseous acceptor phase, by inserting the prefix ‘condensed phase’ to emphasize the use of a solvent acceptor phase – thus yielding CP-MIMS. An initial flow-cell interface with a methanol acceptor phase was characterized, yielding detection limits for model analytes in pptr to ppb, and analyte response times from 1-10 minutes. The flow cell interface was miniaturized into an immersion style CP-MIMS probe (~2 cm), which allowed for analysis of smaller volume samples and improved membrane washing capabilities. Comparable detection limits were observed for the immersion probe, however, it was noticed that significant analyte depletion was observed for samples under 2 mL. In addition, each of the developed membrane interfaces were observed to suffer from ionization suppression effects from complex samples when paired with ESI. Several strategies for mitigating ionization suppression using CP-MIMS are presented, including the use of a continuously infused internal standard present within the acceptor solvent. The developed CP-MIMS system was challenged with the analysis of naphthenic acids (a complex mixture of aliphatic carboxylic acids) directly in contaminated real-world samples. The method used negative ESI to rapidly screen and mass profile aqueous samples for naphthenic acids (as [M-H]-), with sample duty cycles ~20 min. However, it was found that Negative ESI did not differentiate hydroxylated and carboxylated analytes, and both species contributed signal to the total naphthenic acid concentration. To increase method specificity for carboxylic acids, barium ion chemistry was used in conjunction with positive ion tandem mass spectrometry. Common product ions were used to quantify carboxylated analytes, while a qualifier ion was used to confirm the functionality. The increased selectivity afforded by the barium ion chemistry was at the cost of a modest increase in detection limits. CP-MIMS has been established as a technique capable of the direct analysis of real-world samples, and shows promise as a rapid screening method for amenable environmental contaminants and/or biomolecules.

Degree

thesis:*
Level thesis:degree_level
Doctor of Philosophy Ph.D.
Department thesis:degree_department
Department of Chemistry
Year dc:date.issued
2015

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Duncan, Kyle Daniel
Advisors dc:contributor.supervisor
  • Gill, Christopher
  • Fyles, Thomas M.

Subjects

dc:subject × 9

Rights

dc:rights
Statement dc:rights
  • Available to the World Wide Web
Language dc:language.iso
en, English

Identifiers

dc:identifier.*
Dc Identifier Citation
Duncan, K.; McCauley, E.; Krogh, E.; Gill, C., Characterization of a condensed-phase membrane introduction mass spectrometry (CP-MIMS) interface using a methanol acceptor phase coupled with electrospray ionization for the continuous on-line quantitation of polar, low-volatility analytes at trace levels in complex aqueous samples. Rapid Commun. Mass Spectrom., 25, 1141-1151 (2011).
Duncan, K; Willis, M.; Krogh, E.; Gill, C., A miniature condensed-phase membrane introduction mass spectrometry (CP-MIMS) probe for direct and on-line measurements of pharmaceuticals and contaminants in small, complex samples. Rapid Commun. Mass Spectrom., 27, 1213-1221 (2013).
Duncan, K.; Vandergrift, G.; Krogh, E.; Gill, C., Ionization suppression effects with condensed phase membrane introduction mass spectrometry: methods to increase the linear dynamic range and sensitivity. J. Mass Spectrom., 50, 437-443 (2015).
Duncan, K.; D. Letourneau; Vandergrift, G.; Jobst, K.; Reiner, E.; Gill, C.; Krogh, E., A semi-quantitative approach for the rapid screening and mass profiling of naphthenic acids directly in contaminated aqueous samples. J. Mass Spectrom., 51, 44-52 (2016).
Duncan, K.; Volmer, D.; Gill, C.; Krogh, E., Rapid screening of carboxylic acids from waste and surface waters by ESI-MS/MS using barium ion chemistry and on-line membrane sampling. J. Am. Soc. Mass Spectrom., in press (2015).

Chain of custody

source
Harvested from
University of Victoria (Canada)
Base URL
dspace.library.uvic.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Duncan, Kyle Daniel. Condensed phase membrane introduction mass spectrometry. Doctor of Philosophy Ph.D. thesis, 2015. http://hdl.handle.net/1828/6936