Back to search

The University of Western Ontario

Deep-learning-based Denoising and Motion-correction for Low Dose Myocardial CT Perfusion

Abstract

dc:description.abstract

Low-dose myocardial computed tomography perfusion (CTP) imaging is affected by two tightly coupled degradations, elevated noise caused by reduced radiation exposure and residual cardiac motion across the temporal sequence. Although deep learning (DL) based denoising and motion-correction techniques have independently demonstrated strong performance in CT imaging, their sequential application introduces conflicting dependencies. Denoising may suppress subtle anatomical and temporal features required for accurate deformable registration, while registration may distort local intensity statistics essential for effective noise reduction. These interactions remain insufficiently addressed in myocardial CTP imaging, where both structural fidelity and temporal consistency are critical for reliable perfusion assessment. This thesis proposes a unified deep-learning based framework that simultaneously performs noise reduction and residual motion correction for low-dose myocardial perfusion images. The proposed framework integrates a dedicated noise-correction model and a one-shot motion-correction model within a cohesive architecture where the independent models learn noise characteristics and motion patterns. By modeling these degradations concurrently, the approach preserves anatomical detail, temporal enhancement behavior, and spatial correspondence that are often compromised when denoising and registration are applied independently. To further strengthen robustness and stability, an ensemble-based integration strategy is introduced to fuse complementary correction outputs and mitigate variability across differing noise levels and motion patterns. The proposed framework is rigorously evaluated using a comprehensive assessment protocol that includes reference-based image quality metrics, no-reference perceptual measures, quantitative perfusion-based analysis, target registration error, and expert-driven subjective scoring. Experiments are conducted on both synthetically degraded datasets with controlled noise and motion and real low-dose pre-clinical myocardial CTP acquisitions. The results demonstrate consistent improvements in image fidelity, temporal coherence, motion alignment accuracy, and perfusion measurement reliability compared with conventional sequential pre-processing pipelines. Collectively, these findings demonstrate that jointly addressing noise and residual motion within a unified deep-learning framework provides a more effective and clinically relevant solution for low-dose myocardial CT perfusion imaging than existing serialized approaches.

Degree

thesis:*
Name thesis:degree_name
Ph D
Discipline thesis:degree_discipline
Computer Science
Grantor dc:publisher
The University of Western Ontario
Year dc:date.issued
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Hasan, Mahmud
Advisor dc:contributor.advisor
  • El-Sakka, Mahmoud R.

Subjects

dc:subject × 7

Rights

dc:rights
Statement dc:rights
  • Mahmud Hasan. 2026
  • Attribution 4.0 International
Language dc:language.iso
en

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Western University
Base URL
uwo.scholaris.ca/server/oai/request
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Hasan, Mahmud. Deep-learning-based Denoising and Motion-correction for Low Dose Myocardial CT Perfusion. The University of Western Ontario, 2026. https://hdl.handle.net/20.500.14721/39489