Back to search

The University of Western Ontario

Spectral Imaging Techniques for Improved Stent and Iodine Imaging in Cardiac Angiography

Abstract

dc:description.abstract

X-ray imaging is widely used for assessing, diagnosing, and treating coronary artery disease. However, overlapping anatomical structures such as bone and lung tissue may obscure critical features and compromise assessments or treatments. Digital subtraction angiography (DSA) is the gold standard for background suppression of stationary structures (e.g. neuro and extremity imaging) but its clinical utility for cardiac imaging is severely restricted by cardiac and respiratory motions. We propose the use of energy subtraction angiography (ESA) with fast kV-switching and use high-low kV image pairs to develop a maskless subtraction technique that is less sensitive to motion to produce images similar in appearance to DSA. Image quality was evaluated in terms of signal-to-noise ratio (SNR) and compared to DSA for the same entrance exposure. The ESA protocol was optimized to maximize SNR of iodine and nickel stents using a stationary attenuation filter (rather than alternating filters with high-low kV exposures) to simplify implementation. We developed and validated a Fourier-based method to measure x-ray scatter under conditions other methods do not toleratre to incorporate scatter-reduction strategies as part of the ESA protocol development. We show that at non-zero frequencies, important for visualizing small or stenosed vessels, iodine SNR can exceed that of DSA by incorporating a noise reduction algorithm. This suggests that ESA has the potential to produce subtraction images with better SNR than what can be achieved with conventional DSA, for the same patient exposures. To eliminate additional background structures (bone,...) we combine ESA with a synthetic-mask algorithm that identifies pixels where moving vessels are momentarily absent, and stitches these pixels together to generate a "synthetic" mask image. The ESA suppresses soft-tissue, and synthetic mask suppresses remaining structures (bone), resulting in DSA-like images of complex coronary vasculature phantoms. This approach showed excellent results in the phantom study. However, clinical implementation requires a fast kV-switching generator that is not normally available, and real patient motion may impose further challenges. Alternative solutions such as artificial intelligence to suppress background structures were tested and trained on synthetic images, to separate pacemakers from cardiac angiograms, resulting in excellent pacemaker suppression and minimal image degradation.

Degree

thesis:*
Name thesis:degree_name
Ph D
Discipline thesis:degree_discipline
Medical Biophysics
Grantor dc:publisher
The University of Western Ontario
Year dc:date.issued
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Garland, Lisa
Advisor dc:contributor.advisor
  • Cunningham, Ian

Subjects

dc:subject × 6

Rights

dc:rights
Statement dc:rights
  • Lisa Garland, 2026
  • Attribution 4.0 International
Language dc:language.iso
en

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Western University
Base URL
uwo.scholaris.ca/server/oai/request
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Garland, Lisa. Spectral Imaging Techniques for Improved Stent and Iodine Imaging in Cardiac Angiography. The University of Western Ontario, 2026. https://hdl.handle.net/20.500.14721/39894