In Vitro Evaluation of Mechanical Heart Valve Performance Using a Novel Test Chamber in an Automated Mock Circulatory Loop

Abstract

dc:description.abstract

Valvular heart disease (VHD) continues to have significant effects on many people’s lives, with numbers expected to grow tremendously over the next few years. Individuals suffering from severe valvular heart disease usually require a heart valve transplant in order to restore the native valve’s vital unidirectional flow regulation. Therefore, artificial heart valve (AHV) research is of very high importance. Previous research studies have provided substantial input in the realm of AHV design relative to durability, thrombotic and hemolytic potential, and overall functionality. However, modifications continue to be warranted due to limitations in the accuracy and time efficiency of the in vitro physiological flow replication process. The objective of this investigation is to develop and analyze a method of AHV performance evaluation using a novel test chamber within an automated mock circulatory loop. The constructed mock loop was designed to maintain consistency of current industrial and academic research systems while providing innovative loop component control that allows for run-time changes and performance screening to various physiological conditions. Pressure sensors, ultrasonic flow meter, process controls and mechanical feedback sensors are managed via Labview in order to provide sufficient real-time performance analysis during system operation. In addition, a unique mechanical heart valve (MHV) test chamber was constructed to incorporate the test AHV in the mock loop flow path. This research exposes a test tilting disk MHV to a series of 12 heart rate and stroke volume combinations so as to evaluate the system’s effectiveness in pathological condition replication with respect to AHV design research. A Particle Image Velocimetry (PIV) system was utilized to illuminate particles in the flow field and obtain representative vector plots. Results of this study validate the combined experimental test chamber and automated mock circulatory loop as a viable MHV performance evaluation system by using real-time pressure and flow data to analyze system fluid dynamics at the MHV test site. Consequently, the use of this arrangement in MHV performance analysis greatly improves upon time restraints and accuracy concerns associated with currently used manually controlled setups.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
Thesis
Discipline thesis:degree_discipline
Biomedical Engineering

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Walker, Antonio
Contributors dc:contributor
  • Gerald Miller

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • © The Author

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Virginia Commonwealth University
Base URL
scholarscompass.vcu.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Walker, Antonio. In Vitro Evaluation of Mechanical Heart Valve Performance Using a Novel Test Chamber in an Automated Mock Circulatory Loop. Thesis thesis, https://doi.org/10.25772/D5GZ-EE71