Back to search

Virginia Commonwealth University

A NEW APPROACH TO DRIED BLOOD SPOT ANALYSIS FOR NEWBORN SCREENING USING HIGH RESOLUTION LIQUID CHROMATOGRAPHY TANDEM MASS SPECTROMETRY

Abstract

dc:description.abstract

The primary purpose of newborn screening is to quickly identify children that are at risk of having a specific disorder in order to start treatment, prevent early death and reduce the chances of permanent physical or mental damage. The current and widely accepted approach used for identification of metabolism disorders involves a flow injection analysis with mass spectrometry detection of acylcarnitines and amino acids. Although this approach is widely accepted and has shown to be sufficient for identification of multiple metabolism disorders the method is not fully quantitative and results often have to be confirmed by second-tier tests. The primary focus of this research was to improve the accuracy and selectivity of this screening method by employing a high resolution chromatographic separation for the combined analysis of twelve acylcarnitines and seven amino acids. This method is an improvement over the current methodology allowing for separation of key isomers that are diagnostic for different metabolism disorders, reducing the need for multiple second-tier tests to confirm results and shortening the time to diagnosis. In order to further improve the efficiency of newborn screening we developed an in-line desorption device, which allows for direct analysis of DBS eliminating the need for punching disks from the filter paper cards. Our device was the first published paper that demonstrated the ability to directly analyze dried blood spots, without the need for any offline sample processing. Using this device, we validated a method to quantify biomarkers related to Maple Syrup Urine Disease, a disorder that requires a second-tier test for confirmation. To further improve the accuracy of dried blood spot analysis we evaluated a technique to correct the sample volume in low and high hematocrit samples. The level of hematocrit in blood spotted on filter paper cards affects the volume of sample analyzed, leading to errors in accuracy. Diffuse reflectance was used to relate differences in sample hematocrit on dried blood spots. We validated our technique with eighteen donor samples at various levels of hematocrit. Correcting sample volume for hematocrit showed improved precision and accuracy over the standard approach, ultimately reducing the potential to misidentify samples.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
Dissertation
Discipline thesis:degree_discipline
Pharmaceutical Sciences

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Miller, John H., IV
Contributors dc:contributor
  • H. Thomas Karnes

Subjects

dc:subject × 8

Rights

dc:rights
Statement dc:rights
  • © The Author

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Virginia Commonwealth University
Base URL
scholarscompass.vcu.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Miller, John H., IV. A NEW APPROACH TO DRIED BLOOD SPOT ANALYSIS FOR NEWBORN SCREENING USING HIGH RESOLUTION LIQUID CHROMATOGRAPHY TANDEM MASS SPECTROMETRY. Dissertation thesis, https://doi.org/10.25772/0B9T-QM17