In-Shoe Plantar Pressure System To Investigate Ground Reaction Force Using Android Platform

Abstract

dc:description.abstract

Human footwear is not yet designed to optimally relieve pressure on the heel of the foot. Proper foot pressure assessment requires personal training and measurements by specialized machinery. This research aims to investigate and hypothesize about Preferred Transition Speed (PTS) and to classify the gait phase of explicit variances in walking patterns between different subjects. An in-shoe wearable pressure system using Android application was developed to investigate walking patterns and collect data on Activities of Daily Living (ADL). In-shoe circuitry used Flexi-Force A201 sensors placed at three major areas: heel contact, 1st metatarsal, and 5th metatarsal with a PIC16F688 microcontroller and Bluetooth module. This method provides a low-cost instantaneous solution to both wear and records plantar foot simultaneously. Data acquisition used internal local memory to store pressure logs for offline data analysis. Data processing used the perpendicular slope to determine peak pressure and time of index. Statistical analysis can utilize to discover foot deformity. The empirical results in one subject showed weak linearity between normal and fast walk and a significant difference in body weight acceptance between normal and slow walk. In addition, T-test hypothesis testing between two healthy subjects, with , illustrated a significant difference in their Initial Contact pressure and no difference between their peak-to-peak time interval. Preferred Transition Speed versus VGRF was measured in 19 subjects. The experiments demonstrated that vertical GRF averagely increased 18.46% when the speed changed from 50% to 75% of PTS with STD 4.78. While VGRF increased 21.24% when the speed changed from 75% to 100% of PTS with STD 7.81. Finally, logistic regression between 12 healthy subjects demonstrated a good classification with 82.6% accuracy between partial foot bearing and their normal walk.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
Thesis
Discipline thesis:degree_discipline
Engineering

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Mostfa, Ahmed A.
Contributors dc:contributor
  • Weijun Xiao, Ph.D
  • Xuejun Wen. M.D, Ph.D.
  • Peter E. Pidcoe, PT, DPT, Ph.D.
  • Michael J. Cabral, Ph.D.

Subjects

dc:subject × 11

Rights

dc:rights
Statement dc:rights
  • © The Author

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Virginia Commonwealth University
Base URL
scholarscompass.vcu.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Mostfa, Ahmed A.. In-Shoe Plantar Pressure System To Investigate Ground Reaction Force Using Android Platform. Thesis thesis, https://doi.org/10.25772/8NPJ-1A48