Back to search

Virginia Commonwealth University

An Algorithm to Improve Deformable Image Registration Accuracy in Challenging Cases of Locally-Advanced Non-Small Cell Lung Cancer

Abstract

dc:description.abstract

A common co-pathology of large lung tumors located near the central airways is collapse of portions of lung due to blockage of airflow by the tumor. Not only does the lung volume decrease as collapse occurs, but fluid from capillaries also fills the space no longer occupied by air, greatly altering tissue appearance. During radiotherapy, typically administered to the patient over multiple weeks, the tumor can dramatically shrink in response to the treatment, restoring airflow to the lung sections which were collapsed when therapy began. While return of normal lung function is a positive development, the change in anatomy presents problems for future radiation sessions since the treatment was planned on lung geometry which is no longer accurate. The treatment must be adapted to the new lung state so that the radiation continues to accurately target the tumor while safely avoiding healthy tissue. However, to account for the dose delivered previously, correspondences of anatomy between the former image when the lung was collapsed and the re-expanded lung in a current image must be obtained. This process, known as deformable image registration, is performed by registration software. Most registration algorithms assume that identical anatomy is contained in the images and that intensities of corresponding image elements are similar; both assumptions are untrue when collapsed lung re-expands. This work was to develop an algorithm which accurately registers images in the presence of lung expansion. The lung registration method matched CT images of patients aided by vessel enhancement and information of individual lobe boundaries. The algorithm was tested on eighteen patients with lung collapse using physician-specified correspondences to measure registration error. The image registration algorithm developed in this work which was designed for challenging lung patients resulted in accuracy comparable to that of other methods when large lung changes are absent.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
Dissertation
Discipline thesis:degree_discipline
Medical Physics

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Guy, Christopher L
  • <p><a href="https://orcid.org/0000-0001-8937-0910" target="_blank"><img alt="ORCID iD icon" />orcid.org/0000-0001-8937-0910</a></p>
Contributors dc:contributor
  • Geoffrey D. Hugo

Subjects

dc:subject × 5

Rights

dc:rights
Statement dc:rights
  • © The Author

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Virginia Commonwealth University
Base URL
scholarscompass.vcu.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Guy, Christopher L; <p><a href="https://orcid.org/0000-0001-8937-0910" target="_blank"><img alt="ORCID iD icon" />orcid.org/0000-0001-8937-0910</a></p>. An Algorithm to Improve Deformable Image Registration Accuracy in Challenging Cases of Locally-Advanced Non-Small Cell Lung Cancer. Dissertation thesis, https://doi.org/10.25772/4FDP-5H48