Abstract
dc:description.abstractThere is general agreement that the extent of the risk from x-ray examination is related in some way to the radiation dose. As the dose increases, the likelihood of significant biological effects also increases. If a clear correlation between dose and effect is to be established, a convenient and reasonably accurate method of estimating patient’s absorbed doses during common radiographic examinations will be highly needed. A simple method is developed in this project to determine the two important parameters e exposure at skin entrance (ESE) and half value layer (IIVL), which is essential to get reasonably accurate estimates of absorbed doses. Then, the patient’s absorbed doses in common x-ray examinations can be estimated using the computer program. The absorbed doses in 12 routine radiographic projections were calculated by the use of clinical data in MCV Hospital.
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Level thesis:degree_level
- Thesis
- Discipline thesis:degree_discipline
- Biomedical Engineering
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Han, Yang
- Contributors dc:contributor
-
- Ding-Yu Fei
Subjects
dc:subject × 1Rights
dc:rights- Statement dc:rights
-
- © The Author
Identifiers
dc:identifier.*- Identifier
- https://scholarscompass.vcu.edu/etd/5066