Virginia Commonwealth University
Detection of Biomolecules via OCP Measurements using NPG Electrodes
Abstract
dc:description.abstractIn sensing application nanoporous gold (NPG) has attracted much attention. NPG is prepared by dealloying Au:Ag alloys. Characterization was done using scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), and cyclic voltammetry (CV). In this work, the open circuit potential (OCP) of ferricyanide, cysteine, uric acid, and ascorbic acid was measured in phosphate buffer solution (PBS) and biofouling solution containing bovine serum albumin (BSA) at pH 7.4. OCP measurement has been hindered due to biofouling and surface passivation on the metal electrodes. By the use of the NPG electrodes, electrochemical activity can be maintained. From the OCP measurement of cysteine, ascorbic acid, and uric acid, it was seen that mixed potential was dominated by ascorbic acid when multiple components are present in the solution.
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Level thesis:degree_level
- Thesis
- Discipline thesis:degree_discipline
- Chemistry
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Ullah, Borkat
- Contributors dc:contributor
-
- Maryanne M. Collinson, Ph.D.
Subjects
dc:subject × 3Rights
dc:rights- Statement dc:rights
-
- © The Author
Identifiers
dc:identifier.*- Identifier
- https://scholarscompass.vcu.edu/etd/6281