Virginia Commonwealth University
On-Demand Electrically Induced Decomposition of Thin-Film Nitrocellulose Membranes for Wearable or Implantable Biosensor Systems
Abstract
dc:description.abstractImplantable or subcutaneous biosensors used for continuous health monitoring have a limited functional lifetime requiring frequent replacement and therefore may be highly discomforting to the patient and become costly. One possible solution to this problem is use of biosensor arrays where each individual reserve sensor can be activated on-demand when the previous one becomes inoperative due to biofouling or enzyme degradation. Each reserve biosensor in the array is housed in an individual Polydimethylsiloxane (PDMS) well and is protected from exposure to bodily fluids such as interstitial fluid ( ISF) by a thin-film nitrocellulose membrane. Controlled activation is achieved by decomposing over an individual sensor well. Electrically activated thermal decomposition of the nitrocellulose membrane is caused by passing an electric current through an Au/Ti filament placed on top of the membrane. By applying an energy of as low as 7 mJ to the Au/Ti filament with cross-sectional area of 8 x 107 cm2, a current density of ≈ 105 – 106 A/cm2 causes explosive decomposition of thin-film Au/Ti filaments. Having a thermal decomposition temperature of ≈200°C, nitrocellulose is locally heated directly under the Au/Ti filament. This leads to opening of the nitrocellulose membrane within 50 ms allowing for exposure of biosensor to biofluids. 50 ms is sufficiently short to prevent local heating of surrounding tissues and therefore is not a danger to a potential patient.
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Level thesis:degree_level
- Thesis
- Discipline thesis:degree_discipline
- Electrical & Computer Engineering
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Horstmann, Benjamin M
- Contributors dc:contributor
-
- Vitaliy Avrutin
- Umit Ozgur
- Vamsi Yadavalli
Subjects
dc:subject × 13- Long-term Continuous Health Monitoring
- Nitrocellulose
- On-Demand
- Biosensor
- Implantable
- Activation
- Thermal Decomposition
- Electrically Induced Decomposition
- Thin-film
- Biomedical
- Biomedical Devices and Instrumentation
- Electronic Devices and Semiconductor Manufacturing
- Other Electrical and Computer Engineering
Rights
dc:rights- Statement dc:rights
-
- © Benjamin M Horstmann
Identifiers
dc:identifier.*- Identifier
- https://scholarscompass.vcu.edu/etd/6298