Back to search

Virginia Commonwealth University

The Effect of Crowding on the Accuracy of 3D Printed Aligners

Abstract

dc:description.abstract

Purpose: To evaluate the accuracy of three-dimensionally (3D) printed aligners compared to conventional vacuum-formed thermoplastic aligners with varying levels of dental crowding. Methods: Digital intraoral scans of 10 different cases were assigned to their respective groups (n=10, each, 30 total) as follows: no crowding (control), moderate crowding, and severe crowding. Using 3Shape software, digital aligner samples were created in standard tessellation language (STL) file format and randomly 3D printed. The same STL files of each case were also sent to a dental laboratory for the fabrication of vacuum-formed samples, which is the current technology used for manufacturing aligners. The intaglio surfaces of aligners in both groups were scanned using cone beam computed tomography to create STL files, which were compared to the original STL files of the cases using Geomagic Control X software. Absolute deviations from the original file and root mean square values were recorded. A Kruskal-Wallis test was conducted to analyze the difference in average deviation and t-test was repeated for the RMS measure. Significance level was set at 0.05. Results: The amount of crowding did not have an effect on the accuracy of aligners manufactured using 3D printing or conventional vacuum-forming techniques. 3D printed aligners showed less deviation than the vacuum-formed samples (0.1139mm vs 0.1330mm; p-value=0.0007). There was also a statistically significant difference in the variance between the two methods (p-value=0.0014), with a higher variance among aligners manufactured with the vacuum-forming technique than 3D printing method. Conclusion: 3D aligners printed directly from an STL file exhibited better precision and trueness than the aligners fabricated using the conventional vacuum-forming technique. Since accuracy is defined as a combination of precision and trueness, it is concluded that direct printing from an STL file can be used to manufacture aligners.

Degree

thesis:*
Name thesis:degree_name
Master of Science in Dentistry
Level thesis:degree_level
Thesis
Discipline thesis:degree_discipline
Dentistry

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Spangler, Tonya
Contributors dc:contributor
  • Eser Tüfekçi, DDS, MS, PhD, MSHA
  • Dr. Rami Ammoun, DDS, MS, CDT, FACP
  • Sompop Bencharit, DDS, MS, PhD
  • Caroline Carrico, PhD

Subjects

dc:subject × 6

Rights

dc:rights
Statement dc:rights
  • © The Author

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Virginia Commonwealth University
Base URL
scholarscompass.vcu.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Spangler, Tonya. The Effect of Crowding on the Accuracy of 3D Printed Aligners. Thesis thesis, https://doi.org/10.25772/7P8Z-XQ61