Institutional Repository of Vilnius University
Didelių energijų spinduliuočių Si sensorių su vidiniu stiprinimu tyrimas po apšvitų skvarbiaisiais protonais /
Abstract
dc:descriptionSi sensors are widely used in CERN experiments for particle tracking. However, high energy radiation creates defects that determine the formation of energy levels within the band gap and affect the sensors’ operational characteristics. Therefore, new radiation tolerant sensor structures for future experiments are highly desirable. Currently, sensors of pin structure and different types (trip, pixel) are widely employed. However, sensors of pin structure suffer from a decrease in charge collection efficiency. Sensors with internal gain layer (Low Gain Avalanche Detectors - LGADs) appeared to be a promising alternative over sensors of pin structure due to carrier multiplication governed by impact ionization which can compensate the signal drop determined by radiation defects. LGADs are currently being studied within the CERN RD50 program to evaluate the changes in sensor parameters after irradiations with high fluences. This study aimed to examine the recombination, electrostatic and kinetic characteristics of silicon LGAD sensors produced by different vendors and irradiated with penetrative protons of 24 GeV energy in the range of fluences of 10^12 – 10^14 cm^-2. Microwave probed photoconductivity (MW-PC), current-voltage (I-V), capacitance-voltage (C-V) and transient current technique (TCT) methods were employed to thoroughly carry out the research. It was determined that carrier lifetime is inversely proportional to irradiation fluence due to the radiation induced defects which act as recombination centers. It was found that recombination lifetime is shorter in non-irradiated and irradiated with Φ = 10^12 cm^-2 fluence CNM LGAD sensors compared to lifetime values measured in HPK2 LGAD sensors. This can be explained by the presence of higher concentration of defects in starting materials or due to introduction of technological defects during production of the CNM LGAD sensors. Analysis of C-V characteristics revealed the different doping profiles of the investigated sensors. It was concluded that the reduced gain in irradiated sensors can be compensated by enhancement of bias voltage. The HPK2 LGAD sensor appeared to be more suitable for applications in the range of Φ ≤ 10^14 cm^-2 fluences. Meanwhile, it was determined that the CNM LGAD sensors are more sensitive in the range of higher fluences Φ ≥ 10^15 cm^-2.
Degree
thesis:*- Grantor dc:publisher
- Institutional Repository of Vilnius University
- Year dc:date
- 2023
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Markevičius, Rytis,
Rights
dc:rights- Statement dc:rights
-
- info:eu-repo/semantics/openAccess
- Language dc:language
- lit
Identifiers
dc:identifier.*- Repository record dc:identifier
- https://repository.vu.lt/VU:ELABAETD192833422&prefLang=en_US