Pulse characterization using third order autocorrelation and frequency resolved optical gating /
Abstract
dc:descriptionThe fast pace of laser adoption in industry and research from its development in the early 1960s led to a greater demand for higher peak powers. This circumstance influenced the development of mode-locked lasers, as they radiate light in bursts of periodic pulses that are very dense in energy. However mode-locked lasers posed a metrology problem: the pulses were so short that no photodetector had a fast enough response time to measure them. In order to solve this problem a few indirect methods were proposed. One of such methods is autocorrelation. The technique involves splitting the pulse into two copies, then merging them back together in a nonlinear crystal while varying the time delay between the two. Finally, the resulting signal is recorded with a photodiode. If the original pulse shape is known, one can calculate the pulse duration from the result of the overlap. Another widely adopted and commercially available method is frequency resolved optical gating (FROG). This technique is very similar to an autocorrelator, however a spectrometer is used instead of a photodiode. Because of the collected spectrum at each step of the delay, the acquired data can be processed with a reconstruction algorithm, which can retrieve the pulse shape, duration, spectrum and phase. This is considered a full characterization of the pulse. In this work we demonstrate how a custom built FROG reacts to varying pulse shapes, as well as we compare the custom built device with the commercial one. In addition, we explore the possibility of integrating a third order autocorrelator in a FROG setup in order to retrieve the pulse even better. The results of this research showed that the custom built FROG was able to reliably retrieve the laser pulse structure and duration while the pulse was fully compressed (the phase Taylor series term weights GDD = 8.7 and TOD = 3). The most common custom built FROG retrieved pulse duration was 231 fs, while the commercial device had a value of 240 fs. Moreover, the retrieved pulse durations with the custom built FROG were less scattered than the ones from the commercial device. The difference between the custom built and commercial FROG became significant once the pulse was stretched from its compressed form by changing the phase Taylor series GDD term coefficient from 8.7 to 4.7 in the waveshaper settings (GDD = 4.7 and TOD = 3). With these waveshaper settings the commercial device was not able to output 34 a meaningful pulse duration (the pulse duration was 13 fs, which is not possible), while the custom built FROG measured a pulse duration of 1.85 ps. Eventually, the pulse was stretched even more by changing the phase Taylor series TOD term coefficient from 3 to 25 in the waveshaper settings (GDD = 8.7 and TOD = 25). Once again the commercial FROG was not able to retrieve a meaningful pulse duration, while the custom built FROG retrieved the pulse duration of 565 fs as well as the damped side pulse structure. Finally, we explore the potential impact of the photodiode in the third order cross-correlator implementation in the FROG setup, as it poses a greater dynamic range over a spectrometer. On top of that, the cross-correlation of the fundamental beam and second harmonic can help to retrieve the pulse even better due to its asymmetric properties.
Degree
thesis:*- Grantor dc:publisher
- Institutional Repository of Vilnius University
- Year dc:date
- 2023
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Mečėjus, Mindaugas,
Subjects
dc:subject × 1Rights
dc:rights- Statement dc:rights
-
- info:eu-repo/semantics/openAccess
- Language dc:language
- eng
Identifiers
dc:identifier.*- Repository record dc:identifier
- https://repository.vu.lt/VU:ELABAETD192833590&prefLang=en_US