Back to search

Institutional Repository of Vilnius University

Itin trumpų impulsų gaubtinės ir fazės parametrų charakterizavimas D-scan metodu /

Abstract

dc:description

When working with ultrashort laser pulses in the region of few tens of femtoseconds difficulties arise from the inability to directly measure the shape and duration of the pulse. Many indirect correlation based methods exist for this task, each with its benefits and shortcomings. The goal of this study is to create a program for D-scan measurement pulse retrieval, examine it by computer modeling and experimentally with a real OPCPA system. Principle of D-scan operation is based on measuring the pulse second harmonic (SH) spectrum at a number of dispersion values acquired by the pulse. Dispersion is created with variable glass insertions using 2 prisms. As a result 2-dimensional trace representing SH spectrum at different dispersion values is created. D-scan trace resembles FROG trace and contains all the information needed for complete pulse characterization. Since pulse information cannot be analytically computed from measured trace, a program based on differential evolution algorithm was written for pulse retrieval. Performance and reliability of the algorithm was first evaluated using computer modeling experiments. Traces were generated from well known pulses and after reconstruction compared to original inputs. From modeling experiment D-scan method seemed reliable and promising with rms errors of retrieved phases varying from 1 to 3 percent. Measurements of real OPCPA system were performed. Measured pulse shape and duration were found to be consistent (within 0,1 fs) with results of another reliable pulse characterization method Chirp-scan. To further test the ability of d-scan method and written program to correctly retrieve different phase characteristics, various known amounts of third order dispersion (TOD) were added to the test pulse, using Acousto-Optic Programable Dispersion Filter (AOPDF). Retrieval results were later compared to theoretical pulse models for given amount of TOD. Experimental results were rather close to theoretical predictions. After successful phase retrievals, code was modified for both spectral power and phase simultaneous reconstruction. We can then compare retrieved spectrum with measured one to further confirm reliability of measurement technique and reconstruction algorithm. This was possible without an increase in errors, but it takes more time for the algorithm to converge. 28 Despite being slower it is a good option to have, since separate measurement of fundamental spectrum is no longer required.

Degree

thesis:*
Grantor dc:publisher
Institutional Repository of Vilnius University
Year dc:date
2023

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Karvelis, Dominykas,

Rights

dc:rights
Statement dc:rights
  • info:eu-repo/semantics/openAccess
Language dc:language
lit

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Vilnius University
Base URL
epublications.vu.lt/oai
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Karvelis, Dominykas,. Itin trumpų impulsų gaubtinės ir fazės parametrų charakterizavimas D-scan metodu /. Institutional Repository of Vilnius University, 2023. https://repository.vu.lt/VU:ELABAETD192833823&prefLang=en_US