Institutional Repository of Vilnius University
Skaidrių paviršių modifikavimas fosfolipidinėmis membranomis ir jų savybių tyrimas /
Abstract
dc:descriptionOne of the aims of this study was to determine the optimal silanization reaction parameters for silanizing microscope slides using OTS silane solution in heptane, later using them for membrane fusion and analysis with optical microscopy. Silanization and membrane investigation on such transparent surfaces, have not been attempted in previous studies. Investigating the silanization parameters, the following were investigated one by one: reaction temperature, reaction time, silane concentration. Reaction temperatures 30 oC, 40 oC, 60 oC, 70 oC where investigated, the 60 oC reaction temperature was deemed to be optimal; when investigating reaction times, 15 min, 30 min, 45 min and 60 min silanization times were selected, from which, 60 min was the most optimal; lastly, by changing the volumetric OTS silane in heptane concentrations between 0.01 %, 0.1%, 1% and 5% the most optimal one was 0.1%. After determining the optimal glass silanization conditions, membranes of varying composition (DOPC:cholesterol 6:4, DOPC:cholesterol 3:1 and DOPC:cholesterol 1:0) were fused on the silanized glass, then using Cy5 and BODIPY molecular rotors membrane imaging was performed using confocal microscopy and FLIM. When investigating membranes made up from DOPC and cholesterol in a 6:4 ratio dyed using Cy5 confocal and FLIM microscopy showed aggregates of fluorescent cholesterol scattered throughout the membrane and also the existence of two membrane phases which differed in the amount of cholesterol and they’re level of order. Using FLIM imaging cyclodextrins were able to somewhat disperse the cholesterol, evening out the phases. Lastly using the specific property of BODIPY molecular rotors i.e., fluorescence lifetime dependence on membrane viscosity, the effect of cholesterol amount in the DOPC membrane was determined. When there is no cholesterol present, meaning a pure DOPC membrane, the fluorophore exhibited a low fluorescence lifetime, meaning a low viscosity membrane. When the amount of cholesterol present in the membrane was increased to 25% and later to 40%, an increase in the fluorescence lifetimes was observed, when performing FLIM, this meant that the addition of cholesterol into a DOPC membranes made them more viscous.
Degree
thesis:*- Grantor dc:publisher
- Institutional Repository of Vilnius University
- Year dc:date
- 2023
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Momgaudis, Kajus,
Rights
dc:rights- Statement dc:rights
-
- info:eu-repo/semantics/openAccess
- Language dc:language
- lit
Identifiers
dc:identifier.*- Repository record dc:identifier
- https://repository.vu.lt/VU:ELABAETD192839172&prefLang=en_US