Back to search

Institutional Repository of Vilnius University

Ūminės apšvitos jonizuojančiąja spinduliuote biologinė dozimetrija /

Abstract

dc:description

Studies of biological dosimetry have been long and widely used in the event of accidents involving ionizing radiation. Such studies are the only way to accurately estimate the dose of absorbed ionizing radiation when physical data obtained using dosimeters is lacking. The most widely used cytogenetic assays in biological dosimetry are dicentric chromosome, translocation, premature chromosome condensation, and the cytokinesis-block micronucleus assay. There are two main differences between these methods, which determine the possibilities or limitations of their use. The first difference is the time after exposure when the assay performed can still help to accurately determine the dose of absorbed ionizing radiation, and the second is the duration of the assay. The differences between these methods oblige researchers to consider all aspects of the exposure and to choose the most appropriate method to determine the dose of exposure accurately and in a timely manner. Every laboratory performing biodosimetry studies requires a dose-response curve, the construction of which involves exposing cells in vitro and analyzing chromosomal aberrations or micronuclei counts in irradiated cells. Blood cell lymphocytes, which normally do not divide and circulate not only in the bloodstream but also enter various organs, such as lymph nodes and the spleen, are usually used to construct a dose-response curve. These properties of the test cells contribute to the accuracy and sensitivity of the tests performed. In this study, human peripheral blood lymphocytes taken from three people were irradiated with fourteen different photon radiation doses ranging from 0.1 Gy to 5 Gy. Five calibration dose-response curves based on the number of micronuclei, nucleoplasmic bridges, dicentric and ring chromosomes, chromosomal type translocations, and acentric fragments in irradiated cells were made after performing an assay of micronuclei and chromosomal aberrations. Compiled calibration dose-response curves could be used to determine absorbed doses of ionizing radiation in real cases of exposure.

Degree

thesis:*
Grantor dc:publisher
Institutional Repository of Vilnius University
Year dc:date
2023

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Kubiliūtė, Eglė,

Rights

dc:rights
Statement dc:rights
  • info:eu-repo/semantics/openAccess
Language dc:language
lit

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Vilnius University
Base URL
epublications.vu.lt/oai
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Kubiliūtė, Eglė,. Ūminės apšvitos jonizuojančiąja spinduliuote biologinė dozimetrija /. Institutional Repository of Vilnius University, 2023. https://repository.vu.lt/VU:ELABAETD192844384&prefLang=en_US